AC Electrical Characteristics
T
A
= 25˚C
Symbol
(Note 6)
Min
Typ
120
120
120
120
250
180
180
250
Max
200
200
200
200
350
300
300
350
Units
ns
ns
ns
ns
ns
ns
ns
ns
Parameter
Conditions
= 5V, MODE SELECT = 0.8V
RS-422 CONNECTION, V
CC
t
r
Output Rise Time
R
L
= 100Ω, C
L
= 500 pF
(Figure 1 )
t
f
Output Fall Time
R
L
= 100Ω, C
L
= 500 pF
(Figure 1 )
t
PDH
Output Propagation Delay
R
L
= 100Ω, C
L
= 500 pF
(Figure 1 )
t
PDL
t
PZL
t
PZH
t
PLZ
t
PHZ
Output Propagation Delay
TRI-STATE Delay
TRI-STATE Delay
TRI-STATE Delay
TRI-STATE Delay
R
L
= 100Ω, C
L
= 500 pF
(Figure 1 )
R
L
= 450Ω, C
L
= 500 pF, C
C
= 0 pF
(Figure 4 )
R
L
= 450Ω, C
L
= 500 pF, C
C
= 0 pF
(Figure 4 )
R
L
= 450Ω, C
L
= 500 pF, C
C
= 0 pF
(Figure 4 )
R
L
= 450Ω, C
L
= 500 pF, C
C
= 0 pF
(Figure 4 )
DC Electrical Characteristics
(Notes 3, 4, 5, 6)
Parameter
RS-423 CONNECTION, |V
CC
| = |V
EE
|, MODE SELECT
≥
2V
V
IH
V
IL
I
IH
I
IL
V
I
V
O
V
O
V
T
V
T
|V
T
| − | V
T
|
I
X
I
X
+
−
Symbol
Conditions
Min
2
Typ
Max
Units
V
High Level Input Voltage
Low Level Input Voltage
High Level Input Current
Low Level Input Current
Input Clamp Voltage
Output Voltage
Output Voltage
Output Unbalance
Output Leakage Power OFF
Output Leakage Power OFF
Output Short Circuit Current
Output Short Circuit Current
Slew Control Current
Positive Supply Current
Negative Supply Current
V
V
IN
IN
0.8
V
IN
= 2.4V
1
10
−30
V
IN
= 2V
V
IN
= 0.4V
V
IN
= 2.4V
4.0
−4.0
3.6
−3.6
4.4
−4.4
4.1
−4.1
0.02
2
−2
−80
80
0.4
100
−100
−150
150
30
−22
40
100
−200
−1.5
6.0
−6.0
V
IN
≤
15V
V
IN
= 0.4V
I
IN
= −12 mA
R
L
=
∞
, (Note 7)
V
CC
≥
4.75V
R
L
= 450Ω
V
µA
µA
µA
V
V
V
V
V
V
µA
µA
mA
mA
µA
mA
mA
V
CC
≥
4.75V
V
IN
= 0.4V
|V
CC
| = |V
EE
| = 4.75V, R
L
= 450Ω
V
CC
= V
EE
= 0V
V
O
= 6V
V
CC
= V
EE
= 0V
V
O
= 0V
V
O
= 0V
= 0.4V, R
L
=
∞
= 0.4V, R
L
=
∞
V
O
= −6V
V
IN
= 2.4V
V
IN
= 0.4V
I
S+
I
S−
I
SLEW
I
CC
I
EE
±
140
18
−10
Note 2:
“Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. They are not meant to imply that the devices
should be operated at these limits. The tables of “Electrical Characteristics” provide conditions for actual device operation.
Note 3:
Unless otherwise specified, min/max limits apply across the −55˚C to +125˚C temperature range for the DS1691A and across the 0˚C to +70˚C range for
the DS3691. All typicals are given for V
CC
= 5V and T
A
= 25˚C. V
CC
and V
EE
as listed in operating conditions.
Note 4:
All currents into device pins are positive; all currents out of device pins are negative. All voltages are referenced to ground unless otherwise specified.
Note 5:
Only one output at a time should be shorted.
Note 6:
Symbols and definitions correspond to EIA RS-422 and/or RS-423 where applicable.
Note 7:
At −55˚C, the output voltage is +3.9V minimum and −3.9V minimum.
AC Electrical Characteristics
T
A
= 25˚C
Symbol
(Note 6)
Min
Typ
120
120
3.0
3.0
0.06
Max
300
300
Units
ns
ns
µs
µs
µs/pF
Parameter
Conditions
= 5V, V
EE
−5V, MODE SELECT = 2.4V
RS-423 CONNECTION, V
CC
t
r
Rise Time
R
L
= 450Ω, C
L
= 500 pF, C
C
= 0 (Figure
2
)
t
f
Fall Time
R
L
= 450Ω, C
L
= 500 pF, C
C
= 0 (Figure
2
)
t
r
Rise Time
R
L
= 450Ω, C
L
= 500 pF C
C
= 50 pF (Figure
3
)
t
f
Fall Time
R
L
= 450Ω, C
L
= 500 pF C
C
= 50 pF (Figure
3
)
t
rc
Rise Time Coefficient
R
L
= 450Ω, C
L
= 500 pF, C
C
= 50 pF (Figure
3
)
3