Absolute Maximum Ratings
(Note 1)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Supply Voltage (V
CC
)
DC Input Diode Current (I
IK
)
V
I
= −0.5V
V
I
= V
CC
+ 0.5V
DC Input Voltage (V
I
)
DC Output Diode Current (I
OK
)
V
O
= −0.5V
V
O
= V
CC
+ 0.5V
DC Output Voltage (V
O
)
DC Output Source
or Sink Current (I
O
)
DC V
CC
or Ground Current
per Output Pin (I
CC
or I
GND
)
Storage Temperature (T
STG
)
Junction Temperature (T
J
)
CDIP
−0.5V to +7.0V
−20 mA
+20 mA
−0.5V to V
CC
+ 0.5V
−20 mA
+20 mA
−0.5V to V
CC
+ 0.5V
Recommended Operating
Conditions
Supply Voltage (V
CC
)
’AC
’ACT
Input Voltage (V
I
)
Output Voltage (V
O
)
Operating Temperature (T
A
)
54AC/ACT
Minimum Input Edge Rate (∆V/∆t)
’AC Devices
V
IN
from 30% to 70% of V
CC
V
CC
@
3.3V, 4.5V, 5.5V
Minimum Input Edge Rate (∆V/∆t)
’ACT Devices
V
IN
from 0.8V to 2.0V
V
CC
@
4.5V, 5.5V
2.0V to 6.0V
4.5V to 5.5V
0V to V
CC
0V to V
CC
−55˚C to +125˚C
±
50 mA
±
50 mA
−65˚C to +150˚C
175˚C
125 mV/ns
125 mV/ns
Note 1:
Absolute maximum ratings are those values beyond which damage
to the device may occur. The databook specifications should be met, without
exception, to ensure that the system design is reliable over its power supply,
temperature, and output/input loading variables. National does not recom-
mend operation of FACT
®
circuits outside databook specifications.
DC Characteristics for ’AC Family Devices
Symbol
Parameter
V
CC
(V)
V
IH
Minimum High
Level Input Voltage
Maximum Low
Level Input Voltage
Minimum High
Level Output
Voltage
3.0
4.5
5.5
V
IL
3.0
4.5
5.5
V
OH
3.0
4.5
5.5
3.0
4.5
5.5
V
OL
Maximum Low
Level Output
Voltage
3.0
4.5
5.5
3.0
4.5
5.5
I
IN
I
OLD
I
OHD
Maximum Input
Leakage Current
(Note 3) Minimum
Dynamic Output
Current
5.5
5.5
50
−50
mA
mA
V
OLD
= 1.65V Max
V
OHD
= 3.85V Min
5.5
54AC
T
A
=
−55˚C to +125˚C
Guaranteed Limits
2.1
3.15
3.85
0.9
1.35
1.65
2.9
4.4
5.4
(Note 2) V
IN
= V
IL
or V
IH
2.4
3.7
4.7
0.1
0.1
0.1
(Note 2) V
IN
= V
IL
or V
IH
0.50
0.50
0.50
V
µA
12 mA
I
OL
24 mA
24 mA
V
I
= V
CC
, GND
V
I
OUT
= 50 µA
V
I
OH
−12 mA
−24 mA
−24 mA
V
I
OUT
= −50 µA
V
V
OUT
= 0.1V
or V
CC
− 0.1V
V
V
OUT
= 0.1V
or V
CC
− 0.1V
Units
Conditions
±
1.0
5