Absolute Maximum Ratings
(Note 1)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Supply Voltage (V
CC
)
DC Input Diode Current (I
IK
)
V
I
= −0.5V
V
I
= V
CC
+ 0.5V
DC Input Voltage (V
I
)
DC Output Diode Current (I
OK
)
V
O
= −0.5V
V
O
= V
CC
+ 0.5V
DC Output Voltage (V
O
)
DC Output Source
or Sink Current (I
O
)
DC V
CC
or Ground Current
per Output Pin (I
CC
or I
GND
)
−0.5V to +7.0V
−20 mA
+20 mA
−0.5V to V
CC
+ 0.5V
−20 mA
+20 mA
−0.5V to to V
CC
+ 0.5V
Storage Temperature (T
STG
)
Junction Temperature (T
J
)
CDIP
−65˚C to +150˚C
175˚C
Recommended Operating
Conditions
Supply Voltage (V
CC
)
’AC
Input Voltage (V
I
)
Output Voltage (V
O
)
Operating Temperature (T
A
)
54AC
Minimum Input Edge Rate (∆V/∆t)
’AC Devices
V
IN
from 30% to 70% of V
CC
V
CC
@
3.3V, 4.5V, 5.5V
2.0V to 6.0V
0V to V
CC
0V to V
CC
−55˚C to +125˚C
±
50 mA
±
50 mA
125 mV/ns
Note 1:
Absolute maximum ratings are those values beyond which damage
to the device may occur. The databook specifications should be met, without
exception, to ensure that the system design is reliable over its power supply,
temperature, and output/input loading variables. National does not recom-
mend operation of FACT
®
circuits outside databook specifications.
DC Characteristics for ’AC Family Devices
Symbol
Parameter
V
CC
(V)
Guaranteed Limits
V
IH
Minimum High Level
Input Voltage
V
IL
Maximum Low Level
Input Voltage
V
OH
Minimum High Level
Output Voltage
3.0
4.5
5.5
3.0
4.5
5.5
3.0
4.5
5.5
3.0
4.5
5.5
V
OL
Maximum Low Level
Output Voltage
3.0
4.5
5.5
3.0
4.5
5.5
I
IN
I
OLD
I
OHD
I
CC
Maximum Input
Leakage Current
(Note 3) Minimum Dynamic
Output Current
Maximum Quiescent
Supply Current
Note 2:
All outputs loaded; thresholds on input associated with output under test.
Note 3:
Maximum test duration 2.0 ms, one output loaded at a time.
54AC
T
A
= −55˚C to +125˚C
Units
Conditions
2.1
3.15
3.85
0.9
1.35
1.65
2.9
4.4
5.4
V
V
V
V
OUT
= 0.1V
or V
CC
− 0.1V
V
OUT
= 0.1V
or V
CC
− 0.1V
I
OUT
= −50 µA
(Note 2) V
IN
= V
IL
or V
IH
2.4
3.7
4.7
0.1
0.1
0.1
(Note 2) V
IN
= V
IL
or V
IH
0.5
0.5
0.5
V
µA
mA
mA
µA
V
I
= V
CC
, GND
V
OLD
= 1.65V Max
V
OHD
= 3.85V Min
V
IN
= V
CC
or GND
12 mA
I
OL
24 mA
24 mA
V
I
OUT
= 50 µA
V
−12 mA
I
OH
−24 mA
−24 mA
5.5
5.5
5.5
5.5
±
1.0
50
−50
40.0
www.national.com