MILITARY DATA SHEET
MN54AC04-X REV 1A0
(Absolute Maximum Ratings)
(Note 1)
Supply Voltage (Vcc)
-0.5V to +7.0V
DC Input Diode Current (Iik)
Vi = -0.5V
-20 mA
+20 mA
Vi = Vcc +0.5V
DC Input Voltage (Vi)
-0.5V to Vcc +0.5V
DC Output Diode Current (Iok)
Vo = -0.5V
-20 mA
+20 mA
Vo = Vcc +0.5V
DC Output Voltage (Vo)
-0.5V to Vcc +0.5V
+50 mA
DC Output Source or Sink Current (Io)
DC Vcc or Ground Current per Output Pin (Icc or Ignd)
Storage Temperature (Tstg)
+50 mA
-65 C to +150 C
175 C
Junction Temperature (Tj)
CDIP
Note 1: Absolute maximum ratings are those values beyond which damage to the device may
occur. The databook specifications should be met, without exception, to ensure that
the system design is reliable over its power supply, temperature, and output/input
loading varibles. National does not recommend operation of FACT TM circuits outside
databook specifications.
Recommended Operating Conditions
Supply Voltage (Vcc)
2.0V to 6.0V
Input Voltage (Vi)
0V to Vcc
0V to Vcc
Output Voltage (Vo)
Operating Temperature (Ta)
-55 C to +125 C
Minimum Input Edge Rate (Delta V/Delta t)
AC Devices
Vin from 30% to 70% of Vcc
Vcc @ 3.0V, 4.5V, 5.5V
125 mV/ns
3