DC Electrical Characteristics
Conditions
CL = 50 pF,
Symbol
Parameter
Min
Max
Units
VCC
RL = 500Ω
VOLP
VOLV
Quiet Output Maximum Dynamic VOL
Quiet Output Minimum Dynamic VOL
1.1
V
V
5.0
5.0
TA = 25˚C (Note 5)
TA = 25˚C(Note 5)
-0.45
Note 5: Max number of outputs defined as (n). n − 1 data inputs are driven 0V to 3V. One output at LOW.
AC Electrical Characteristics
54ABT
TA = −55˚C to +125˚C
VCC = 4.5V to 5.5V
CL = 50 pF
Symbol
Parameter
Units
Min
Max
fmax
Max Clock
150
MHz
ns
Frequency
tPLH
tPHL
tPZH
tPZL
tPHZ
tPLZ
Propagation Delay
CP to On
1.5
1.5
0.8
1.2
1.5
1.5
6.9
6.9
6.5
6.5
9.6
7.2
Output Enable Time
ns
Output Disable Time
ns
AC Operating Requirements
54ABT
TA = −55˚C to +125˚C
VCC = 4.5V to 5.5V
CL = 50 pF
Symbol
Parameter
Units
Min
1.3
1.3
1.5
1.5
3.3
3.3
Max
ts(H)
ts(L)
th(H)
th(L)
tw(H)
tw(L)
Setup Time, HIGH
or LOW Dn to CP
Hold Time, HIGH
or LOW Dn to CP
Pulse Width, CP
HIGH or LOW
ns
ns
ns
Capacitance
Symbol
Parameter
Typ
Units
pF
Conditions (TA = 25˚C)
CIN
COUT (Note 6)
Input Capacitance
Output Capacitance
5.0
VCC = 0V
VCC = 5.0V
11.0
pF
Note 6: C
is measured at frequency f = 1 MHz, per MIL-STD-883B, Method 3012.
OUT
www.national.com
4