AC Electrical Characteristics
=
=
=
VEE −4.2V to −5.7V, VCC GND, VTTL +4.5V to +5.5V
=
=
=
Symbol
Parameter
TC −55˚C
TC +25˚C
TC +125˚C
Units
Conditions
Notes
Min
1.50
Max
Min
1.60
Max
Min
Max
=
tPLH
tPHL
Propagation Delay
Data to Output
5.00
4.70
1.70
5.70
ns
CL 50 pF
(Notes 7,
8, 9)
Figures 1, 3
Note 7: F100K 300 Series cold temperature testing is performed by temperature soaking (to guarantee junction temperature equals −55˚C), then testing immediately
after power-up. This provides “cold start” specs which can be considered a worst case condition at cold temperatures.
Note 8: Screen tested 100% on each device at +25˚C, temperature only, Subgroup A9.
Note 9: Sample tested (Method 5005, Table I) on each manufactured lot at +25˚C, Subgroup A9, and at +125˚C and −55˚C temperatures, Subgroups A10 and A11.
Note 10: Not tested at +25˚C, +125˚C, and −55˚C temperature (design characterization data).
Switching Waveform
DS100314-6
FIGURE 1. Propagation Delay
www.national.com
4