AC Electrical Characteristics
=
=
=
VEE −4.2V to −5.7V, VCC VCCA GND
=
=
=
Symbol
Parameter
TC −55˚C
TC +25˚C
TC +125˚C Units
Conditions
Notes
Min
Max
Min
Max
Min
Max
tPLH
Propagation Delay
(Notes 7, 8, 9,
11)
0.30
1.80
0.40
1.60
0.40
1.80
ns
ns
tPHL
tTLH
tTHL
Data to Output
Transition Time
Figures 1, 2
0.30
1.20
0.30
1.20
0.30
1.20
(Note 10)
20% to 80%, 80% to
20%
Note 7: F100K 300 Series cold temperature testing is performed by temperature soaking (to guarantee junction temperature equals −55˚C), then testing immediately
after power-up. This provides “cold start” specs which can be considered a worst case condition at cold temperatures.
Note 8: Screen tested 100% on each device at +25˚C temperature only, Subgroup A9.
Note 9: Sample tested (Method 5005, Table I) on each mfg. lot at +25˚C, Subgroup A9, and at +125˚C and −55˚C temperatures, Subgroups A10 and A11.
Note 10: Not tested at +25˚C, +125˚C, and −55˚C temperature (design characterization data).
Note 11: The propagation delay specified is for single output switching. Delays may vary up to 200 ps with multiple outputs switching.
Test Circuitry
DS100309-5
Notes:
=
=
V
, V
+2V, V
−2.5V
CC CCA
EE
=
L1 and L2 equal length 50Ω impedance lines
=
R
50Ω terminator internal to scope
T
Decoupling 0.1 µF from GND to V and V
CC EE
All unused outputs are loaded with 50Ω to GND
=
C
L
Fixture and stray capacitance ≤ 3 pF
FIGURE 1. AC Test Circuit
Switching Waveforms
DS100309-6
FIGURE 2. Propagation Delay and Transition Times
3
www.national.com