AC Electrical Characteristics
(Continued)
Note 8:
Screen tested 100% on each device at +25˚C temperature only, Subgroup A9.
Note 9:
Sample tested (Method 5005, Table I) on each manufactured lot at +25˚C, Subgroup A9, and at +125˚C and −55˚C temperatures, Subgroups A10 and A11.
Note 10:
Not tested at +25˚C, +125˚C, and −55˚C temperature (design characterization data).
Note 11:
The propagation delay specified is for single output switching. Delays may vary up to 100 ps with multiple outputs switching.
Test Circuitry
DS100303-5
Notes:
V
CC
, V
CCA
= +2V, V
EE
= −2.5V
L1 and L2 = equal length 50Ω impedance lines
R
T
= 50Ω terminator internal to scope
Decoupling 0.1 µF from GND to V
CC
and V
EE
All unused outputs are loaded with 50Ω to GND
C
L
= Fixture and stray capacitance
≤
3 pF
FIGURE 1. AC Test Circuit
Switching Waveforms
DS100303-6
FIGURE 2. Propagation Delay and Transition Times
www.national.com
4