CF5018 series
SPECIFICATIONS
Absolute Maximum Ratings
V
SS
= 0V
Parameter
Supply voltage range
Input voltage range
Output voltage range
Operating temperature range
Storage temperature range
Output current
Symbol
V
DD
V
IN
V
OUT
T
opr
T
STG
I
OUT
Condition
Rating
−
0.5 to +7.0
−
0.5 to V
DD
+ 0.5
−
0.5 to V
DD
+ 0.5
−
40 to +85
−
65 to +150
20
Unit
V
V
V
°
C
°
C
mA
Recommended Operating Conditions
V
SS
= 0V, f
≤
80MHz, C
L
≤
30pF
Parameter
Supply voltage range
Input voltage range
Operating temperature range
Symbol
V
DD
V
IN
T
OPR
Condition
Rating
2.25 to 2.75
V
SS
to V
DD
−
40 to +85
Unit
V
V
°
C
SEIKO NPC CORPORATION —3