CF5015 series
SPECIFICATIONS
Absolute Maximum Ratings
V
SS
= 0V
Parameter
Supply voltage range
Input voltage range
Output voltage range
Operating temperature range
Storage temperature range
Output current
Symbol
V
DD
V
IN
V
OUT
T
opr
T
STG
I
OUT
Condition
Rating
−
0.5 to +7.0
−
0.5 to V
DD
+ 0.5
−
0.5 to V
DD
+ 0.5
−
40 to +85
−
65 to +150
12
Unit
V
V
V
°
C
°
C
mA
Recommended Operating Conditions
2.5V operation (CF5015AL
×
/CF5015BL
×
)
V
SS
= 0V
Parameter
Supply voltage range
Input voltage range
Operating temperature range
Oscillation frequency range
Symbol
V
DD
V
IN
T
OPR
f
O
CF5015AL
×
CF5015BL
×
CF5015AL
×
Output frequency range
f
OUT
CF5015BL
×
C
L
≤
15pF
C
L
≤
30pF
C
L
≤
15pF
C
L
≤
30pF
Condition
Rating
2.25 to 2.75
V
SS
to V
DD
−
40 to +85
4 to 60
12 to 60
0.25 to 60
0.25 to 50
0.75 to 60
0.75 to 50
Unit
V
V
°
C
MHz
MHz
MHz
MHz
MHz
MHz
3V operation (CF5015BL
×
)
V
SS
= 0V
Parameter
Supply voltage range
Input voltage range
Operating temperature range
Oscillation frequency range
Output frequency range
Symbol
V
DD
V
IN
T
OPR
f
O
f
OUT
C
L
≤
15pF
C
L
≤
30pF
Condition
Rating
2.7 to 3.6
V
SS
to V
DD
−
40 to +85
12 to 60
0.75 to 60
0.75 to 50
Unit
V
V
°
C
MHz
MHz
MHz
5V operation (CF5015BL
×
)
V
SS
= 0V
Parameter
Supply voltage range
Input voltage range
Operating temperature range
Oscillation frequency range
Output frequency range
Symbol
V
DD
V
IN
T
OPR
f
O
f
OUT
C
L
≤
30pF
Condition
Rating
4.5 to 5.5
V
SS
to V
DD
−
40 to +85
12 to 60
0.75 to 60
Unit
V
V
°
C
MHz
MHz
SEIKO NPC CORPORATION —3