5042 series
DC Characteristics (5042B1A to B6A)
V
= 1.60V to 2.25V, V = 0V, Ta = −40°C to +85°C, C = 15pF unless otherwise noted.
LOUT
DD
SS
Rating
Parameter
Symbol
Conditions
Unit
MIN
TYP
MAX
5042B1A (f
= fo), Measurement circuit 1,
OUT
–
1.7
3.4
mA
mA
mA
mA
mA
mA
µA
no load, INHN = HIGH, fo = 48MHz, V = 1.8V
DD
5042B2A (f
= fo/2), Measurement circuit 1,
OUT
–
–
–
–
–
–
1.5
1.4
1.4
1.3
1.3
–
3.3
3.2
3.1
3.1
3.0
10
no load, INHN = HIGH, fo = 48MHz, V = 1.8V
DD
5042B3A (f
= fo/4), Measurement circuit 1,
OUT
no load, INHN = HIGH, fo = 48MHz, V = 1.8V
DD
Operating-mode current
*1
I
DD
consumption
5042B4A (f
= fo/8), Measurement circuit 1,
OUT
no load, INHN = HIGH, fo = 48MHz, V = 1.8V
DD
5042B5A (f
= fo/16), Measurement circuit 1,
OUT
no load, INHN = HIGH, fo = 48MHz, V = 1.8V
DD
5042B6A (f
= fo/32), Measurement circuit 1,
OUT
no load, INHN = HIGH, fo = 48MHz, V = 1.8V
DD
Standby-mode current
consumption
I
Measurement circuit 1, INHN = LOW
ST
HIGH-level output voltage
LOW-level output voltage
V
Q pin, Measurement circuit 3, I = −4mA
OH
V −0.4
DD
–
–
–
0.4
10
V
V
OH
V
Q pin, Measurement circuit 3, I = 4mA
OL
–
–
OL
Q = V
–
µA
µA
V
DD
Measurement circuit 4,
INHN = LOW
Output leakage current
I
Z
Q = V
−10
–
–
SS
HIGH-level input current
LOW-level input current
V
0.7V
–
–
–
IH
DD
INHN pin, Measurement circuit 5
V
–
0.3V
V
IL
DD
R
INHN = V
0.4
50
1.5
100
10
MΩ
kΩ
PU1
SS
INHN pull-up resistance
Measurement circuit 6
R
INHN = 0.7V
200
PU2
DD
*1. The consumption current I (C
) with a load capacitance (C
is the output frequency.
) connected to the Q pin is given by the following equation, where I is the no-
DD
DD LOUT
LOUT
load consumption current and f
I
OUT
–3
(C
DD LOUT
) [mA] = I [mA] + C
DD
[pF] × V [V] × f
[MHz] × 10
LOUT
DD
OUT
SEIKO NPC CORPORATION—6