Nichia STSE-CC2036B-2
<Cat.No.061031>
(4) Soldering Conditions
· The LEDs can be soldered in place using the reflow soldering method.
Nichia cannot make a
guarantee on the LEDs after they have been assembled using the dip soldering method.
· Recommended soldering conditions
Hand Soldering
Reflow Soldering
120 ~ 150°C
Pre-heat
Temperature
Soldering time
300°C Max.
Pre-heat time
Peak temperature
Soldering time
Condition
120 seconds Max.
240°C Max.
3 seconds Max.
(one time only)
10 seconds Max.
refer to Temperature- profile.
½ Although the recommended soldering conditions are specified in the above table, reflow or hand
soldering at the lowest possible temperature is desirable for the LEDs.
½ A rapid-rate process is not recommended for cooling the LEDs down from the peak temperature.
[Temperature-profile (Surface of circuit board)]
[Recommended soldering pad design]
Use the following conditions shown in the figure. Use the following conditions shown in the figure.
2.5 ~ 5°C / sec.
240°C Max.
10sec. Max.
Pre-heating
2.5 ~ 5°C / sec.
120 ~ 150°C
60sec.Max.
Above 200°C
1.8
1.0
4.6
1.8
(Unit : mm)
120sec.Max.
· Repairing should not be done after the LEDs have been soldered.
When repairing is unavoidable,
a double-head soldering iron should be used. It should be confirmed beforehand whether the
characteristics of the LEDs will or will not be damaged by repairing.
· Reflow soldering should not be done more than one time.
· When soldering, do not put stress on the LEDs during heating.
· After soldering, do not warp the circuit board.
(5) Cleaning
· It is recommended that isopropyl alcohol be used as a solvent for cleaning the LEDs.
When using
other solvents, it should be confirmed beforehand whether the solvents will dissolve the package and the
resin or not.
· Do not clean the LEDs by the ultrasonic.
Freon solvents should not be used to clean the LEDs because of worldwide regulations.
When it is absolutely necessary, the influence of ultrasonic
cleaning on the LEDs depends on factors such as ultrasonic power and the assembled condition.
Before cleaning, a pre-test should be done to confirm whether any damage to the LEDs will occur.