Maximum altitude................................. 2,000 m  
Specifications  
Pollution Degree....................................  
Indoor use only.  
2
Specifications are subject to change without notice.  
Bus Interface  
Form factor............................................ x1 PCI Express  
Slot compatibility.................................. x1, x4, x8, and x161  
Storage Environment  
NI PXI-8360  
Ambient temperature range............. -20 to 70 °C  
(tested in accordance with  
PCI Express slots  
1Some motherboard manufacturers intend the x16 slot for graphics use and preinstall a graphics board.  
Check with the motherboard manufacturer for alternative graphics solutions if using the x16 slot for a  
nongraphics board.  
IEC-60068-2-1 and IEC-60068-2-2;  
meets MIL-PRF-28800F Class 3 limits)  
Power Requirements  
Relative humidity range.................... 5 to 95%, noncondensing  
(tested in accordance  
with IEC-60068-2-56)  
Power Rail  
+3.3 V  
Typical Current  
1.500 A  
5 mA  
Maximum Current  
1.750 A  
20 mA  
20 mA  
0 mA  
NI PXI-8360  
NI PCIe-8361  
Ambient temperature range............. -20 to 70 °C  
(tested in accordance with  
IEC-60068-2-1 and IEC-60068-2-2)  
Relative humidity range.................... 5 to 95%, noncondensing  
+5 V  
+12 V  
5 mA  
-12 V  
0 mA  
NI PCIe-8361  
NI PCIe-8362  
+3.3 V  
1.800 A  
0 A  
2.000 A  
0 A  
+3.3 VAUX  
+12 V  
0 A  
0 A  
(tested in accordance  
with IEC-60068-2-56)  
+3.3 V  
580 mA  
10 mA  
0 A  
1.040 A  
50 mA  
0 A  
+3.3 VAUX  
+12 V  
NI PCIe-8362  
Ambient temperature range............. -40 to 70 °C  
(tested in accordance with  
IEC-60068-2-1 and IEC-60068-2-2)  
Relative humidity range.................... 5 to 95%, noncondensing  
Physical  
Dimensions  
NI PXI-8360....................................... 10.0 by 16.0 cm (3.9 by 6.3 in.)  
NI PCIe-8361..................................... 10.7 by 17.5 cm (4.4 by 6.9 in.)  
NI PCIe-8362..................................... 9.93 by 7.11 cm (3.91 by 2.8 in.)  
Slot requirements  
(tested in accordance  
with IEC-60068-2-56)  
Shock and Vibration  
NI PXI-8360  
NI PXI-8360....................................... One 3U PXI system controller slot  
NI PCIe-8361 and PCIe-8362 ............ One PCI Express slot  
Maximum cable length ......................... 7 m  
Operating............................................... 30 g peak, half-sine, 11 ms pulse  
(tested in accordance with  
Compatibility......................................... Fully compatible with the PXI Hardware  
Specification, Revision 2.1, and the  
IEC-60068-2-27; test profile developed  
in accordance with MIL-PRF-28800F)  
Random Vibration  
PCI Express Specification, Revision 1.0a  
Operating.......................................... 5 to 500 Hz, 0.3 grms  
Nonoperating.................................... 5 to 500 Hz, 2.4 grms  
(tested in accordance with  
Operating Environment  
NI PXI-8360, PCIe-8361, PCIe-8362  
Ambient temperature range............. 0 to 55 °C  
(tested in accordance with  
IEC-60068-2-64; nonoperating test  
profile exceeds the requirements of  
IEC-60068-2-1 and IEC-60068-2-2;  
MIL-PRF-28800F, Class 3)  
meets MIL-PRF-28800F Class 3 low  
Note: For full EMC compliance, operate this device with shielded cabling. In addition, all covers  
and filler panels must be installed. Refer to the Declaration of Conformity (DoC) for this product  
for any additional regulatory compliance information. To obtain the DoC for this product, visit  
ni.com/certification, search by model number or product line, and click the appropriate link in  
the Certification column.  
temperature limit and MIL-PRF-28800F  
Class 2 high temperature limit)  
Relative humidity range.................... 10 to 90%, noncondensing  
(tested in accordance with IEC-60068-2-56)  