12-Bit E Series Multifunction
DAQ Specifications
12-Bit E Series Specifications
Specifications – NI 607xE, NI 606xE, NI 6040E, NI 602xE
(continued)
Digital I/O
6025E
All others
Number of Channels
32 input/output
8 input/output
Triggers
Analog Triggers
607xE
6062E
6040E
602xE
Maximum (V)
0.8
5.0
0.4
Number of Triggers
1
Compatibility .................................................... 5 V TTL
Power-on state ................................................. Input; (high-impedance)
Digital logic levels
P0.<0..7>
Level
Input low voltage
Input high voltage
Output low voltage (I
out
= 24 mA)
Output high voltage (I
out
= -13 mA)
P1.<0..7>, P2.<0..7>, P3.<0..7>
Level
Input low voltage
Input high voltage
Output low voltage (Iout = 2.5 mA)
Output high voltage (Iout = -2.5 mA)
Minimum (V)
0
2.2
3.7
Maximum (V)
0.8
5.0
0.4
Minimum (V)
0
2.0
4.35
None
Purpose
Analog input ..............................................
Analog output ............................................
General-purpose counter/timers ...............
Source...............................................................
Level
Internal source, AI<0..15/63>....................
External source, PFI 0/AI START TRIG ..........
Slope.................................................................
Resolution.........................................................
Bandwidth (-3 dB)
Device
607xE
6062E
6040E
Start and stop trigger, gate, clock
Start trigger, gate, clock
Source, gate
All analog input channels, PFI 0/AI START TRIG
±Full-scale
±10 V
Positive or negative; software selectable
8 bits, 1 in 256
External Source
7 MHz
2.5 MHz
3 MHz
6025E
All others
Data Transfers
Interrupts, programmed I/O
Programmed I/O
Internal Source
2 MHz
500 kHz
650 kHz
Hysteresis......................................................... Programmable
Transfer rate (1 word = 8 bits)
Maximum with NI-DAQ, system dependent
Transfer Rate
DAQPad-6070E
All others
5 kwords/s
50 kwords/s
Digital Triggers (All Devices)
Purpose
Analog input ..............................................
Analog output ............................................
General-purpose counter/timers ...............
Source...............................................................
Compatibility ....................................................
Response ..........................................................
Pulse width.......................................................
Start and stop trigger, gate, clock
Start trigger, gate, clock
Source, gate
PFI <0..9>, RTSI <0..6>
5 V/TTL
Rising or falling edge
10 ns minimum
Data Acquisition and
Signal Conditioning
Constant sustainable rate................................ 1 to 10 kwords/s, system dependent
Timing I/O
Number of channels
Up/down counter/timers ...........................
Frequency scaler........................................
Resolution
Up/down counter/timers ...........................
Frequency scaler........................................
Compatibility ....................................................
Base clocks available
Up/down counter/timers ...........................
Frequency scaler........................................
Base clock accuracy .........................................
Maximum source frequency
Up/down counter/timers ...........................
Minimum source pulse duration ......................
Minimum gate pulse duration..........................
Data transfers ..................................................
*Except DAQCard and USB DAQPad
2
1
24 bits
4 bits
5 V/TTL
20 MHz and 100 kHz
10 MHz and 100 kHz
±0.01%
20 MHz
10 ns, edge-detect mode
10 ns, edge-detect mode
DMA*, interrupts, programmed I/O
External Input For Digital Or Analog Trigger (PFI0/TRIG1)
Impedance
6062E .........................................................
607xE, 6040E .............................................
Coupling............................................................
Protection
Digital trigger ............................................
12 kΩ
10 kΩ
DC
-0.5 to V
cc
+ 0.5 V
Calibration
Recommended warm-up time.......................... 15 minutes; 30 minutes for DAQCard and DAQPad
Calibration interval........................................... 1 year
Onboard calibration reference
DC level ..................................................... 5.000 V (±3.5 mV) over full operating temperature,
actual value stored in EEPROM
Temperature coefficient ............................ ±5 ppm/°C maximum
Long-term stability .................................... ±15 ppm/ 1000 h
236