欢迎访问ic37.com |
会员登录 免费注册
发布采购

777867-06 参数 Datasheet PDF下载

777867-06图片预览
型号: 777867-06
PDF下载: 下载PDF文件 查看货源
内容描述: 便携E系列多功能DAQ 12位或16位,高达1.25 MS / s的16个模拟输入 [Portable E Series Multifunction DAQ 12 or 16-Bit, up to 1.25 MS/s, 16 Analog Inputs]
分类和应用:
文件页数/大小: 4 页 / 445 K
品牌: NI [ NATIONAL INSTRUMENTS CORPORATION ]
 浏览型号777867-06的Datasheet PDF文件第2页浏览型号777867-06的Datasheet PDF文件第3页浏览型号777867-06的Datasheet PDF文件第4页  
Portable E Series Multifunction DAQ
12 or 16-Bit, up to 1.25 MS/s, 16 Analog Inputs
E Series – Portable
• 16 analog inputs at up to 1.25 MS/s,
12 or 16-bit resolution
• Up to 2 analog outputs at up to
1 MS/s, 12 or 16-bit resolution
• 8 digital I/O lines (TTL/CMOS); two
24-bit counter/timers
• Analog and digital triggering
• 4 analog input signal ranges
• NI-DAQ Measurement
Services simplifies configuration
and measurements
Operating Systems
• Windows 2000/NT/XP
Recommended Software
• LabVIEW
• LabWindows/CVI
• Measurement Studio
• VI Logger
Other Compatible Software
• Visual Basic, C/C++, and C#
Measurement Services
Software (included)
• NI-DAQ 7
Products
DAQCard-6036E
DAQCard-6062E
DAQCard-6024E
DAQPad-6052E
DAQPad-6070E
DAQPad-6020E
1
For
Bus
PCMCIA
PCMCIA
PCMCIA
IEEE 1394
IEEE 1394
USB
Analog
Inputs
16 SE/8 DI
16 SE/8 DI
16 SE/8 DI
16 SE/8 DI
16 SE/8 DI
16 SE/8 DI
Input
Max
Resolution Sampling Rate
16 bits
200 kS/s
12 bits
500 kS/s
12 bits
200 kS/s
16 bits
333 kS/s
12 bits
1.25 MS/s
12 bits
100 kS/s
Input
Range
±0.05 to ±10 V
±0.05 to ±10 V
±0.05 to ±10 V
±0.05 to ±10 V
±0.05 to ±10 V
±0.05 to ±10 V
Analog
Outputs
2
2
2
2
2
2
Output
Resolution
16 bits
12 bits
12 bits
16 bits
12 bits
12 bits
Output
Rate
1 kS/s
850 kS/s
1 kS/s
333 kS/s
1 MS/s
100 kS/s
Output
Range
±10 V
±10 V
±10 V
±10 V
±10 V
±10 V
Digital
I/O
8
8
8
8
8
8
Counter/
Timers
2
2
2
2
2
2
Triggers
Digital
Analog, digital
Digital
Analog, digital
Analog, digital
Digital
Measurment
Services Software
1
NI-DAQmx
NI-DAQmx
NI-DAQmx
Traditional NI-DAQ
Traditional NI-DAQ
Traditional NI-DAQ
up-to-date information on NI-DAQ, visit ni.com/support/daq/versions.htm
Table 1. NI Portable E Series Model Guide
Overview and Applications
National Instruments portable E Series DAQ products deliver the
same functionality available in PCI and PXI E Series DAQ devices –
in a portable format. The DAQPad devices are hot swappable and
available in up to three different configurations. The 15 cm enclosure
is ideal for desktop or portable applications and features a 68-pin
shielded connector. The 30 cm enclosure with mass termination
offers a low-profile package that fits under your laptop computer.
It features a 68-pin shielded connector to connect signals from our
SCC modular signal conditioning products or from our CA-1000
custom connectivity enclosure. The 30 cm enclosure with BNC
connectivity is ideal for applications where portability and quick
connectivity are needed, such as in-vehicle automotive or aircraft
testing and portable data logging.
NI DAQCards are Type II, PC Card compliant and provide
performance equivalent to their PCI or PXI counterparts. However, due
to their compact design, they can be used in applications where space
constraints are an important concern, such as field service and research.
Highly Accurate Hardware Design
NI portable E Series DAQ devices provide the functionality of
E Series data acquisition devices in a portable format:
Temperature Drift Protection Circuitry
– Designed with components
that minimize the effect of temperature changes on measurements to
less than 0.0010% of reading per °C.
Resolution Improvement Technologies
– Carefully designed noise
floor maximizes the resolution.
Onboard Self-Calibration
– Precise voltage reference included for
calibration and measurement accuracy. Self-calibration is completely
software controlled, with no potentiometers to adjust.
NI DAQ-STC
– Timing and control ASIC designed to provide more
flexibility, lower power consumption, and a higher immunity to noise
and jitter than off-the-shelf counter/timer chips.
NI MITE
– ASIC designed to optimize data transfer for multiple
simultaneous operations using bus mastering with DMA channels,
interrupts, or programmed I/O.