SCXI Terminal Blocks
TBX Terminal Block
Selection Guide
Use the following steps to select the correct combination
of TBX terminal blocks and cables for your SCXI system:
1. Select the required terminal blocks –
For each
SCXI module, use table 1 to select the proper TBX
terminal block. If a TBX-13xx terminal block is not
available for your SCXI module, select the appropriate
number of general-purpose TBX-24F feedthrough
terminal blocks.
2. Select cabling –
For each TBX terminal block, table
1 lists the cable needed to connect the TBX terminal
block to the SCXI module. Shielded cables are available
in lengths of 1, 2, and 5 m. If using the TBX-1303, you
also have the option to build a custom cable using the
SBS-96F backshell kit. For each TBX-1303 for which you
will build a custom cable, select two SBS-96F kits.
If using the TBX-24F, you will use discrete wires to
connect the TBX-24F to an SCXI front-mounting terminal
block. Therefore, select the appropriate SCXI front-
mounting terminal block for each SCXI module that
will use the TBX-24F.
3. Rack-mount accessory (optional) –
If mounting
for 19 in. rack enclosures is needed, use table 2 to select
the appropriate number of TBX-RM1 rack-mount kits.
4. Calibration –
Calibration of cold-junction sensors
and attenuation terminal blocks is available for some
devices. For more information, please visit
ni.com/calibration.
Terminal Block
TBX-1303
TBX-1325, TBX-1326, TBX-1328, TBX-1329, TBX-24F, CB-50
Module
SCXI-1100
SCXI-1102
SCXI-1102B
SCXI-1102C
SCXI-1104/C
SCXI-1120
SCXI-1120D
SCXI-1126
SCXI-1125
SCXI-1121
SCXI-1122
SCXI-1124
SCXI-1127
SCXI-1128
SCXI-1129
SCXI-1140
SCXI-1141
SCXI-1142
SCXI-1143
SCXI-1160
SCXI-1161
SCXI-1162/HV
SCXI-1163/R
SCXI-1180
SCXI-1181
SCXI-1181K
SCXI-1503
SCXI-1520
SCXI-1540
SCXI-1581
1
Cold-junction
Terminal Blocks
SCXI-1303
2
SCXI-1300
3
SCXI-1308
BNC-2095
TC-2095
SCXI-1300
SCXI-1305
SCXI-1320
SCXI-1327
SCXI-1328
SCXI-1338
SCXI-1304/5
SCXI-1313A
SCXI-1320
SCXI-1327
SCXI-1328
SCXI-1338
SCXI-1320
SCXI-1321
SCXI-1327
SCXI-1328
SCXI-1305
SCXI-1322
SCXI-1325
SCXI-1331
SCXI-1332
SCXI-1333
SCXI-1334
SCXI-1335
SCXI-1336
SCXI-1337
SCXI-1339
SCXI-1301
SCXI-1304
SCXI-1305
SCXI-1304
SCXI-1305
SCXI-1301
SCXI-1324
SCXI-1326
SCXI-1302
SCXI-1300
SCXI-1301
SCXI-1306
SCXI-1314
SCXI-1315
SCXI-1300
CJC
1
Sensor




















Other Terminal Block Functions
Isothermal, signal ground referencing, and open thermocouple detection
Current input, 249
resistor across each input
BNC connectors, signal ground referencing
Thermocouple plugs, signal ground referencing, isothermal
BNC connectors, AC/DC coupling and ground referencing
Extends signal input range to 300 V
rms
, switch configurable per channel
Isothermal, high-accuracy design for thermocouples
Current input, 249
resistor across each input
BNC connectors, AC/DC coupling and ground referencing
Extends signal input range to 150 V
rms
, programmable per channel
Extends signal input range to 300 V
rms
, switch configurable per channel
Isothermal, high-accuracy design for thermocouples
Current input, 249
resistor across each input
Offset nulling and shunt calibration for strain gages
Extends signal input range to 300 V
rms
, switch configurable per channel
Isothermal, high-accuracy design for thermocouples
BNC connectors, AC/DC coupling and signal ground referencing
Set up an 8 column by 4 row matrix
Configures SCXI-1129 as quad, 4 x 16 (2-wire) matrix
Configures SCXI-1129 as 4 x 64 (2-wire) matrix
Configures SCXI-1129 as 8 x 32 (2-wire) matrix
Configures SCXI-1129 as 16 x 16 (2-wire) matrix
Configures SCXI-1129 as a dual 8 x 16 (2-wire) matrix
Configures SCXI-1129 as a dual 4 x 32 (2-wire) matrix
AC/DC coupling and signal ground referencing (configurable per channel)
BNC connectors, AC/DC coupling and signal ground referencing
AC/DC coupling and signal ground referencing (configurable per channel)
BNC connectors, AC/DC coupling and signal ground referencing
Screw terminals located in module
50-pin terminal block
Quarter-bridge completion/shunt resistor
compensation (CJC) sensor for thermocouple measurements.
2
Recommended for thermocouples; includes isothermal design and high-precision
CJC sensor.
3
Recommended for RTDs when using both SCXI-1102 and SCXI-1581.
Table 3. SCXI-13xx, TC, and BNC Selection Guide
Width Required (TBX-RM1 Rack-Mount)
One-half
One-third
Module
SCXI-1100, SCXI-1102B/C, SCXI-1140, SCXI-1141, SCXI-1181
SCXI-1120, SCXI-1120D, SCXI-1121, SCXI-1126, SCXI-1181
Connector and Shell Assembly
SCXI-1310
SCXI-1330
Table 2. Rack-Mount Widths of TBX Terminal Blocks
Table 4. Custom Cabling Accessories
BUY ONLINE
at
ni.com
or
CALL 800 813 3693 (U.S.)
2