Portable, Modular Signal Conditioning Modules  
NI SCC-AO10 Isolated Analog Output  
Specifications  
SCC-AO10  
Output Characteristics  
Number of output channels................ 1 nonreferenced single ended  
Input range.......................................... ±10 V  
Output range ....................................... ±10 V  
Current drive ....................................... ±30 mA  
Gain nonlinearity................................. 0.5ꢀ of full-scale output range  
Propagation delay ............................... 10 µs  
Output noise........................................ 2.5 mVrms typ; 4 mVrms max  
Bandwidth........................................... >23 kHz  
Model  
SCC-AO10  
Channel  
1
Description  
±10 V isolated voltage output  
Part Number  
777459-50  
Slew rate............................................. 1 V/µs  
The National Instruments SCC-AO10 is a single-channel isolated analog  
voltage output module with an output range of ±10 V. Each channel of  
the NI SCC-AO10 is referenced to its own isolated ground, allowing up to  
±0 VDC of common-mode voltage between grounds (channel-to-channel  
or channel-to-chassis). In addition, the SCC-AO10 increases the output  
current drive capacity of an M Series, E Series, or B Series multifunction  
DAQ device to ±30 mA. Because the modules are isolated, you can  
cascade two SCC-AO10 modules for an output range of ±20 V. There is  
a maximum of two SCC-AO10 modules per carrier.  
Safety Isolation  
Channel-to-earth  
(signal + common mode) ................ ±0 VDC, CAT I  
Environment  
Operating temperature ....................... 0 to 50 °C  
Relative humidity ................................ 10 to 90ꢀ noncondensing  
Stability  
Output offset temperature  
coefficient................................... 300 µV/°C  
Gain temperature coefficient ......... 300 ppm/°C  
Note: Use the SCC-AO10 with only multifunction DAQ devices that have  
Power Requirements  
Analog................................................. 180 mW  
Digital.................................................. 1.15 W  
analog outputs.  
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)  