欢迎访问ic37.com |
会员登录 免费注册
发布采购

777459-11 参数 Datasheet PDF下载

777459-11图片预览
型号: 777459-11
PDF下载: 下载PDF文件 查看货源
内容描述: SCC配置指南 [SCC Configuration Guide]
分类和应用:
文件页数/大小: 17 页 / 4120 K
品牌: NI [ National Instruments ]
 浏览型号777459-11的Datasheet PDF文件第9页浏览型号777459-11的Datasheet PDF文件第10页浏览型号777459-11的Datasheet PDF文件第11页浏览型号777459-11的Datasheet PDF文件第12页浏览型号777459-11的Datasheet PDF文件第14页浏览型号777459-11的Datasheet PDF文件第15页浏览型号777459-11的Datasheet PDF文件第16页浏览型号777459-11的Datasheet PDF文件第17页  
Portable, Modular Signal Conditioning Modules  
NI SCC-FV01 Frequency Input Module  
NI SCC-CI20 Current Input  
Model  
Channel  
Description  
Part Number  
Model  
Channel  
Description  
Part Number  
SCC-FV01  
2
Frequency-to-voltage conversion (0 to 100 Hz)  
777459-32  
SCC-CI20  
2
0 to 20 mA current input  
777459-05  
The National Instruments SCC-FV01 is a dual-channel frequency-to-  
voltage conversion module that accepts ±10 V signals up to 100 Hz. The  
output scales linearly with the input frequency, and goes to 0 V with a  
DC input signal. Each channel triggers on the incoming signal using a  
threshold of 0 V and a hysteresis of 200 mV. For isolated solutions,  
consider using the SCC-AI03 cascaded with the NI SCC-FV01.  
The National Instruments SCC-CI20 is a dual-channel module that  
accepts two 0 to 20 mA or 4 to 20 mA current loop inputs. Each  
independent channel of the NI SCC-CI20 includes a precision 249 Ω  
current conversion resistor that converts a 0 to 20 mA signal into a  
0 to 5 V signal. Each channel includes a differential instrumentation  
amplifier with low-impedance outputs for maximum scanning rates by  
the multifunction DAQ device, and bias resistors for handling both  
floating and ground-referenced current sources. The SCC-CI20 also  
includes two spare 249 Ω resistors.  
Specifications  
SCC-FV01  
When you install the SCC-CI20 in the SC-2345, the carrier routes the  
two output voltages to two input channels of the DAQ device, channels x  
and x+8, where x is 0 through 7. For example, if you install the module in  
the J1 socket of the SC-2345, the output voltages are routed to input  
channels 0 and 8 of the DAQ device.  
Input Characteristics  
Number of input channels .................. 2 referenced single ended  
Input range.......................................... 200 mV1 to 10 V  
Input coupling ..................................... DC  
Minimum input frequency................... 0 Hz  
Minimum input pulse width  
(5 V pulse train) .............................. 1.5 µs  
Overvoltage protection ....................... ±40 VAC + DC (powered on  
or off)  
Specifications  
SCC-CI20  
Input impedance  
Input Characteristics  
Signal > threshold .......................... 400 kΩ  
Signal < threshold .......................... 10 MΩ  
Threshold............................................. Zero crossing  
Hysteresis............................................ 200 mV  
Number of channels............................ 2 differential  
Input range.......................................... 0 to 20 mA  
Output range ....................................... 0 to 5 V  
Gain error ............................................ ±0.1ꢀ of reading maximum  
Offset error.......................................... ±0.± mV maximum  
Input resistor....................................... 249 Ω, 0.05ꢀ, 0.25 W  
Full power bandwidth......................... 10 kHz  
Transfer Characteristics  
Rise/fall time ...................................... 80 ms (0 to +±3ꢀ)  
Step response ..................................... 220 ms at 90ꢀ; 3±0 ms at 99ꢀ  
Output offset....................................... 5 mV max  
Output offset temperature  
coefficient....................................... 10 ppm/°C  
Gain error temperature coefficient..... 100 ppm/°C  
Nonlinearity......................................... 0.015ꢀ full scale  
Output ripple ....................................... 30 mVpp at 10 Hz  
Output range ....................................... 0 to +10 V  
Recommended warm-up time............. 5 minutes  
Power Requirements  
Analog................................................. 100 mW  
Power Requirements  
Analog................................................. 100 mW  
1Recommended; minimum 100 mV.  
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)  