Portable Modular DAQ Systems  
SCC Signal Conditioning Overview  
Removable Connectors  
J16 slots J9 is controlled by a single DIO line of the DAQ device.  
All SCC modules except the SCC-TC01 have removable screw- The digital I/O lines of a DAQ device are line configurable, so you can  
terminal connectors. This simplifies signal connection and module choose any combination of eight digital I/O modules and relays.  
swapping for quick reconfiguration. The SCC-TC01 has  
a
minithermocouple connector for easy sensor connection and more Accessories  
accurate cold-junction sensing.  
The SC-2345 with configurable connectors offers accessories such as a  
panel-mount kit, a rack-mount kit for 19 in. cabinets, a stacking kit, and  
a handle kit for use with multiple carriers and with DAQPad devices.  
Connectivity Options  
The SC-2345 with Configurable Connectors is a shielded carrier that  
offers custom I/O and interface panelettes to match your sensors. Software  
With interface panelettes, you can add hardware controls and You can develop your SCC DAQ System applications very quickly  
displays to your system. Blank panelettes are also available to fill and easily with the NI-DAQ driver software or with LabVIEW.  
unused positions or for customization. See page 267 for complete NI-DAQ is the robust driver software that makes it easy to access the  
panelette options.  
functionality of your data acquisition and signal conditioning  
hardware, whether you are a beginner or an advanced user. Helpful  
features include:  
Number of  
Channels  
SCC Module  
SCC-AI Series  
SCC-A10  
SCC-LP Series  
SCC-TC Series  
SCC-RTD01  
Input Types  
Isolated analog input  
100 ꢀ ꢁ10ꢂ1 attenuatorꢃ  
Lowpass filters  
Thermocouples, 100 mꢀ  
RTD ꢁ2, 3, and 4-wireꢃ  
2
2
2
1
2
2
1
2
1
1
2
1
1
2
2
1
Automatic Code Generation – DAQ Assistant is an interactive guide  
that steps you through configuring, testing, and programming  
measurement tasks and generates the necessary code automatically.  
Cleaner Code Development – Basic and advanced software functions  
have been combined into one easy-to-use yet powerful set to help  
you build cleaner code and move from basic to advanced  
applications without replacing functions.  
SCC-SG Series  
SCC-ACC01  
SCC-CI20  
SCC-AOIO  
SCC-CO20  
SCC-FꢀO1  
SCC-DIO1  
SCC-DO01  
SCC-SG11  
SCC-FT01  
Strain gauges and force/load/torque sensors  
Accelerometers  
0 to 20 mA current input  
Isolated voltage output, 10 ꢀ  
Isolated current output, 0 to 20 mA  
Frequency-to-voltage  
High-Performance Driver Engine – Software-timed single-point input  
(typically used in control loops) with NI-DAQ achieves rates of up  
to 50 kHz. NI-DAQ also delivers maximum I/O system throughput  
with a multithreaded driver.  
Isolated digital input  
Isolated digital output  
Shunt calibration  
Unconditioned or custom  
SCC-RLY01  
Switch 5 A at 30 ꢀDC or 250 ꢀAC  
Table 1. SCC Signal Conditioning Modules  
Test Panels – NI-DAQ lets you test all four device functions before  
you begin development with test panels, accessible either from  
your development environment, such as LabVIEW, or the  
configuration utility.  
Power Options  
Each SCC system offers three different power options. Depending on  
the total power consumption of the SCC modules installed, you can  
power the SCC system from (1) the 5 VDC line of a DAQ device or  
an external 5 VDC source, (2) an AC power source, or (3) an external  
7 to 42 VDC power supply. To determine which power option is best  
for your application, see the SC-2345 shielded carrier (page 254) or  
visit the online SCC Advisor at ni.com/advisors  
Scaled Channels – Easily scale your voltage data into the proper  
engineering units using the NI-DAQ Channel Wizard. By choosing  
from a list of common sensors and signals or creating your own  
custom scale.  
LabVIEW Integration – All NI-DAQ functions offer the waveform data  
type, which carries acquired data and timing information directly  
into more than 400 built-in analysis routines in LabVIEW, and  
displays the results in engineering units on a graph.  
Signal Routing  
Many of the SCC analog input modules are dual-channel modules. Operating System Compatibility  
When a dual-channel module is installed in the SC-2345, the two All modules work with Windows 2000/NT/XP  
output voltages of the module are routed to two input channels of  
the DAQ device, channels X and X+8, where X is any integer For information on other operating systems such as Linux and  
0 through 7. For example, if a dual-channel module is installed in the Mac OS X see page 187.  
J1 socket of the SC-2345, the output voltages are routed to input  
channels 0 and 8 of the E Series DAQ device.  
Digital modules connect directly to individual digital I/O lines of the  
DAQ device. For example, a digital output module installed in any of  
252 National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com  
 复制成功!