 浏览型号74HCT245D-Q100的Datasheet PDF文件第7页浏览型号74HCT245D-Q100的Datasheet PDF文件第8页浏览型号74HCT245D-Q100的Datasheet PDF文件第9页浏览型号74HCT245D-Q100的Datasheet PDF文件第10页浏览型号74HCT245D-Q100的Datasheet PDF文件第12页浏览型号74HCT245D-Q100的Datasheet PDF文件第13页浏览型号74HCT245D-Q100的Datasheet PDF文件第14页浏览型号74HCT245D-Q100的Datasheet PDF文件第15页  
74HC245-Q100; 74HCT245-Q100  
Nexperia  
Octal bus tranceiver; 3-state  
Table 9.  
Dynamic characteristics type 74HCT245-Q100  
GND = 0 V; for test circuit, see Figure 7.  
Symbol  
Tamb = 25 C  
tpd  
Parameter  
Conditions  
Min  
Typ  
Max  
Unit  
[1]  
propagation delay  
An to Bn or Bn to An;  
see Figure 5  
VCC = 4.5 V  
-
-
-
12  
10  
16  
22  
-
ns  
ns  
ns  
VCC = 5.0 V; CL = 15 pF  
[2]  
[3]  
[4]  
[5]  
ten  
tdis  
tt  
enable time  
OE to An or OE to Bn;  
VCC = 4.5 V; see Figure 6  
30  
disable time  
OE to An or OE to Bn;  
CC = 4.5 V; see Figure 6  
-
-
-
16  
5
30  
12  
-
ns  
ns  
pF  
V
transition time  
An, Bn; VCC = 4.5 V;  
see Figure 5  
CPD  
power dissipation capacitance  
VI = GND to VCC 1.5 V  
30  
Tamb = 40 C to +85 C  
[1]  
[2]  
tpd  
ten  
propagation delay  
VCC = 4.5 V; see Figure 5  
-
-
-
-
28  
38  
ns  
ns  
enable time  
disable time  
transition time  
OE to An or OE to Bn;  
VCC = 4.5 V; see Figure 6  
[3]  
[4]  
tdis  
tt  
OE to An or OE to Bn;  
VCC = 4.5 V; see Figure 6  
-
-
-
-
38  
15  
ns  
ns  
An, Bn; VCC = 4.5 V;  
see Figure 5  
T
amb = 40 C to +125 C  
[1]  
[2]  
tpd  
ten  
propagation delay  
enable time  
VCC = 4.5 V; see Figure 5  
-
-
-
-
33  
45  
ns  
ns  
OE to An or OE to Bn;  
VCC = 4.5 V; see Figure 6  
[3]  
[4]  
tdis  
tt  
disable time  
OE to An or OE to Bn;  
VCC = 4.5 V; see Figure 6  
-
-
-
-
45  
18  
ns  
ns  
transition time  
An, Bn; VCC = 4.5 V;  
see Figure 5  
[1] tpd is the same as tPLH and tPHL  
[2] en is the same as tPZH and tPZL  
[3] tdis is the same as tPLZ and tPHZ  
[4] tt is the same as tTHL and tTLH  
.
t
.
.
.
[5] CPD is used to determine the dynamic power dissipation (PD in W):  
PD = CPD VCC2 fi N + (CL VCC2 fo) where:  
fi = input frequency in MHz;  
fo = output frequency in MHz;  
CL = output load capacitance in pF;  
VCC = supply voltage in V;  
N = number of inputs switching;  
(CL VCC2 fo) = sum of outputs.  