74HC4067-Q100; 74HCT4067-Q100
Nexperia
16-channel analog multiplexer/demultiplexer
PQEꢀꢉꢂ
ꢄꢄꢂ
ꢍꢄꢎ
5
ꢁ
21
ꢍȍꢎ
ꢀꢂ
ꢉꢂ
ꢈꢂ
ꢇꢂ
ꢄꢂ
9
6:
ꢍꢆꢎ
ꢍꢇꢎ
9
&&
(
9
,/
<Q
=
*1'
9
LV
,
6:
ꢂ
ꢄꢏꢃ
ꢇꢏꢊ
ꢈꢏꢅ
ꢉꢏꢆ
ꢀꢏꢂ
9
ꢍ9ꢎ
LVꢁ
ꢀꢀꢁDDJꢂꢊꢊ
Vis = 0 V to VCC
Vis = 0 V to VCC
(1) VCC = 4.5 V
(2) VCC = 6.0 V
(3) VCC = 9.0 V
VSW
RON
=
---------
ISW
Fig 8. Test circuit for measuring RON
Table 7. Static characteristics 74HC4067-Q100
Fig 9. Typical RON as a function of input voltage Vis
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Vis is the input voltage at a Yn or Z terminal, whichever is assigned as an input.
Vos is the output voltage at a Yn or Z terminal, whichever is assigned as an output.
Symbol
Tamb = 25 C
VIH
Parameter
Conditions
Min
Typ
Max Unit
HIGH-level input voltage
VCC = 2.0 V
VCC = 4.5 V
VCC = 6.0 V
VCC = 9.0 V
VCC = 2.0 V
VCC = 4.5 V
VCC = 6.0 V
VCC = 9.0 V
VI = VCC or GND
VCC = 6.0 V
VCC = 10.0 V
1.5
1.2
2.4
3.2
4.7
0.8
2.1
2.8
4.3
-
-
V
V
V
V
V
V
V
V
3.15
4.2
-
6.3
-
VIL
LOW-level input voltage
-
-
-
-
0.5
1.35
1.80
2.70
II
input leakage current
-
-
-
-
0.1 A
0.2 A
IS(OFF)
OFF-state leakage current
VCC = 10.0 V; VI = VIH or VIL;
VSW = VCC GND; see Figure 10
per channel
all channels
-
-
-
-
-
-
0.1 A
0.8 A
0.8 A
IS(ON)
ON-state leakage current
VCC = 10.0 V; VI = VIH or VIL;
VSW = VCC GND; see Figure 11
74HC_HCT4067_Q100
All information provided in this document is subject to legal disclaimers.
©
Nexperia B.V. 2017. All rights reserved
Product data sheet
Rev. 1 — 22 May 2015