74HC4067-Q100; 74HCT4067-Q100
Nexperia
16-channel analog multiplexer/demultiplexer
Table 4.
Limiting values …continued
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Ptot total power dissipation
Conditions
Min
Max
Unit
Tamb = 40 C to +125 C
SO24 package
[2]
[3]
[3]
[4]
-
-
-
-
-
500
500
500
500
100
mW
mW
mW
mW
mW
SSOP24 package
TSSOP24 package
DHVQFN24 package
per switch
P
power dissipation
[1] To avoid drawing VCC current out of terminal Z, when switch current flows in terminals Yn, the voltage drop across the bidirectional
switch must not exceed 0.4 V. If the switch current flows into terminal Z, no VCC current will flow out of terminals Yn. In this case there is
no limit for the voltage drop across the switch, but the voltages at Yn and Z may not exceed VCC or GND.
[2] For SO24 package: Ptot derates linearly with 8 mW/K above 70 C.
[3] For TSSOP24 package: Ptot derates linearly with 5.5 mW/K above 60 C.
[4] For DHVQFN24 package: Ptot derates linearly with 4.5 mW/K above 60 C.
9. Recommended operating conditions
Table 5.
Recommended operating conditions
Symbol Parameter
74HC4067-Q100
Conditions
Min
Typ
Max
Unit
VCC
VI
supply voltage
2.0
5.0
10.0
VCC
VCC
625
139
83
V
input voltage
GND
-
V
VSW
t/V
switch voltage
GND
-
V
input transition rise and fall rate
VCC = 2.0 V
VCC = 4.5 V
VCC = 6.0 V
VCC = 10.0 V
-
-
1.67
-
ns
ns
ns
ns
-
-
-
-
31
Tamb
ambient temperature
40
+25
+125 C
74HCT4067-Q100
VCC
VI
supply voltage
4.5
GND
GND
-
5.0
-
5.5
VCC
VCC
139
V
input voltage
V
VSW
t/V
Tamb
switch voltage
-
V
input transition rise and fall rate
ambient temperature
VCC = 4.5 V
1.67
+25
ns
40
+125 C
74HC_HCT4067_Q100
All information provided in this document is subject to legal disclaimers.
©
Nexperia B.V. 2017. All rights reserved
Product data sheet
Rev. 1 — 22 May 2015