UC2/UD2 SERIES  
NOTE ON CORRECT USE  
1. Notes on contact load  
used within the specified temperature range. Use of a relay  
at a temperature outside this range may adversely affect  
insulation or contact performance.  
- If the relay is used for a long period of time in highly humid  
(RH 85% or higher) environment, moisture may be absorbed  
into the relay. This moisture may react with the NOx and  
SOx generated by glow discharges that occur when the  
contacts are opened or closed, producing nitric or sulfuric  
acid. If this happens, the acid produced may corrode the  
metallic parts of the relay, causing operational malfunction.  
Make sure that the contact load is within the specified range;  
otherwise, the lifetime of the contacts will be shortened  
considerably.  
Note that the running performance shown is an example,  
and that it varies depending on parameters such as the  
type of load, switching  
frequency, driver circuit, and  
ambient temperature under the actual operating conditions.  
Evaluate the performance by using the actual circuit before  
using the relay.  
2. Driving relays  
- If the internal connection diagram of a relay shows + and -  
symbols on the coil, apply the rated voltage to the relay in  
the specified direction. If a rippled DC current source is  
used, abnormalities such as beat at the coil may occur.  
- The maximum voltage that can be applied to the coil of the  
- If any material containing silicon (silicon rubber, silicon oil,  
and silicon based coating material) is used in the  
neighborhood of relay, there is some possibility that these  
materials will emit silicon gas that will penetrate the relay. In  
this case, the switching contact may generate silicon  
compounds on the surface of contacts. This silicon  
compound may result in contact failure. Avoid use of relay in  
such an environment.  
relay  
Generally, the higher the voltage applied to the coil, the  
shorter the operating time. Note, however, that high  
voltage also increases the bounce of the contacts and  
varies depending on the ambient temperature.  
a
-
Because the operating temperature range varies  
the contact opening and closing frequency, which may  
shorten the lifetime of the contacts.  
- If the driving voltage waveform of the relay coil rises and  
falls gradually, the inherent performance of the relay may not  
be fully realized. Make sure that the voltage waveform  
instantaneously rises and falls as a pulse.  
depending on the humidity, use the relay in the temperature  
range illustrated in the figure below. Prevent the relay from  
being frozen and avoid the generation of condensation.  
85  
80  
60  
Nominal  
coil voltage  
Humidity  
(%RH)  
40  
20  
5
0
-60 -40 -20  
0 20 40 60 80 100  
<1msec.  
<1msec.  
Temperature (°C )  
-
The relay maintains constant sealability under normal  
atmospheric pressure (810 to 1,200 hpa). Its sealability may  
be degraded or the relay may be deformed and malfunction  
if it is used under barometric conditions exceeding the  
specified range.  
- For a latching relay, apply a voltage to the coil according to  
the polarity specified in the internal connection diagram of  
the relay.  
- If a current is applied to the coil over a long period of time,  
the coil temperature rises, promoting generation of organic  
gas inside the relay, which may result in faulty contacts. In  
this case, use of a latching relay is recommended.  
- The operating time and release time indicate the time  
required for each contact to close after the voltage has been  
applied to or removed from the coil. However, because the  
relay has a mechanical structure, a bounce state exists at  
the end of the operating and release times. Furthermore,  
because additional time is required until the contact  
stabilizes after being in a high-resistance state, care must be  
taken when using the relay at high speeds.  
- The same applies when the relay is stored or transported.  
Keep the upper-limit value of the temperature to which the  
relay is exposed after it is removed from the carton box to  
within 50°C.  
- Permanent magnets are used in polarized relays. For this  
reason, when magnets, transformers, or speakers are  
located nearby the relay characteristics may change and  
faulty operations may result.  
- If excessive vibration or shock is applied to the relay, it may  
malfunction and the contacts remain closed. Vibration or  
shock applied to the relay during operation may cause  
considerable damage to or wearing of the contacts. Note that  
operation of a snap switch mounted close to the relay or  
shock due to the operation of magnetic solenoid may also  
3. Operating environment  
- Make sure that the relay mounted in the application set is  
13  
●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.  
●Please request for a specification sheet for detailed product data prior to the purchase.  
●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.  
2007.08.03 P0894EMDD03VOL03E  