CHAPTER 7 8-BIT TIMER
Figure 7-13. Timing of Interval Timer Operation with 8-Bit Resolution
(When Timer 60 Match Signal Is Selected for Timer 50 Count Clock)
Timer 60
count clock
M
M
M
00H
00H
01H
N
00H
00H
00H
M
TM60
Clear
Clear
Clear
Clear
N
CR60
TCE60
Count start
INTTM60
Input clock to timer 50
(timer 60 match signal)
Y
00H
00H
00H
01H
Y − 1
Y
TM50
CR50
Y
TCE50
INTTM50
TO60
Count start
TO50
148
User’s Manual U15075EJ1V0UM00