SX
NOTES
1. Coil operating power
5. Packing style
6. Automatic insertion
1) As a general rule, only a pure DC pow-
er supply should be used for the coil drive.
2)To ensure proper operation, the voltage
applied to both terminals of the coil should
be ±5% (at 20°C 68°F) the rated operating
voltage of the coil. Also, be aware that the
pick-up and drop-out voltages will fluctu-
ate depending on the ambient tempera-
ture and operating conditions.
3) The ripple factor for the voltage applied
to the coil should be less than 5%.
4) For set and reset latching relays, the
rated operating voltage should be applied
to the coil for 10 ms or more.
1) The relay is packed in a tube with the
relay orientation mark on the left side, as
shown in the figure below.
To maintain the internal function of the re-
lay, the chucking pressure should not ex-
ceed the values below.
Chucking pressure in the direction A:
4.9 N {500 gf} or less
Chucking pressure in the direction B:
9.8 N {1 kgf} or less
Chucking pressure in the direction C:
9.8 N {1 kgf} or less
Orientation (indicates PIN No.1)stripe
Stopper (gray)
Stopper (green)
2) Tape and reel packing
(1) Tape dimensions
C
B
mm inch
A
Relay polarity bar
4.0±0.1
.157±.004
1.50+0.1 dia.
(Z type)
1.75±0.1
.069±.004
.059+0.003dia.
.0
2.0±0.1
.079±.004
0.40±0.1
.016±.004
24.0±0.3
.945±.012
15.5±0.1
Max. 20.0
.787
.610±.004
2. Coil connection
Please chuck the
portion.
When connecting coils, refer to the wiring
diagram to prevent mis-operation or mal-
function.
11.5±0.1
.453±.004
10.8±0.2
.425±.008
16.0±0.1
10.0±0.1
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be also
avoided.
.630±.004 .394±.004
SX relays
Tape coming out direction
General tolerance ±0.1 mm .004 inch
3. External magnetic field
(2) Dimensions of plastic reel
mm inch
Since SX relays are highly sensitive polar-
ized relays, their characteristics will be af-
fected by a strong external magnetic field.
Avoid using the relay under that condition.
21±0.8 dia.
.827±.031 dia.
2.0±0.5
.079±.020
4. Cleaning
In automatic cleaning, cleaning with the
boiling method is recommended. Avoid ul-
trasonic cleaning which subject the relay
to high frequency vibrations. It may cause
the contacts to stick.
lt is recommended that a fluorinated hy-
drocarbon or other alcoholic solvent be
used.
100±1 dia.
3.937±.039 dia.
370±2 dia.
14.567±.079 dia.
13±0.2 dia.
.512±.008 dia.
2.0±0.2
.079±.008
24.4 +02
.961 0+.079
For Cautions for Use, see Relay Technical Information (Page 48 to 76).