SCP1000 Series
Electrical Characteristics
Vdd = 2.7 V and ambient temperature unless otherwise specified
Parameter
Condition
Min.
Supply voltage Vdd
2.4
Current Consumption
High resolution mode
High speed mode
Ultra low power mode
Power down
@ 500 kHz
Typ
25
25
3.5
200
Max.
3.3
Units
V
µA
µA
µA
nA
pF
pF
kHz
kHz
µs
Output Load
Digital Pins Input Capacitance
SPI Clock Frequency
I
2
C Clock Frequency
Data Transfer Time
500
50
1.6
500
400
@ 500 kHz
120
Performance Characteristics
(4
Parameter
Operating Pressure Range
Operating Temperature
Resolution
(5
Relative Pressure Accuracy
(5
Absolute Pressure Accuracy
(5
Absolute Pressure Accuracy
(5
Long-term Stability
Digital pressure output data
word length
Digital temperature output data
word length
Pressure Data Output Refresh
Rate
Temp. Resolution
Temp. Accuracy
Condition
Nominal
High resolution mode
High speed mode
600 hPa...1200 hPa
+10 °C ... +40 °C
600 hPa...1200 hPa
+10 °C ... +40 °C
300 hPa...1200 hPa
-20 °C ... +70 °C
12 months
-50
-150
-200
+100
19
14
High resolution mode
High speed mode
-2
1.8
9
0.2
±1
0.5
+2
Min.
30
-20
Typ
Max.
120
+70
3
6
+50
+150
+200
Units
kPa
°C
Pa
Pa
Pa
Pa
Pa
Pa
bits
bits
Hz
Hz
°C
°C
1.5
3
Note 4 Soldered components. Detailed information about the effect of soldering and mounting can be found in SCP1000 Pressure
Sensor Assembly Instructions (Technical Note 51)
Note 5 Typical = Median, Min. /Max. = 95% of the components within the population
VTI Technologies Oy
www.vti.fi
Subject to changes
2/7