SCP1000 Series
Interface Options
Communication interface is pre-programmed in the factory and it can be either SPI (Serial Peripheral
Interface) or I
2
C (Inter-Integrated Circuit). The SPI interface is a full duplex 4 wire interface and the
connection between the MCU and SCP1000 is achieved using MOSI, MISO, SCK and CSB. The I
2
C
interface is slave-only half duplex two-wire interface available on SDA and SCL pins.
Interface Options
The SCP1000 Pressure sensor has 4 normal operation modes plus power down mode.
Mode
High resolution
High speed
Ultra low power
Low power
Power Down
Pressure measurement
Continues
Continues
Periodical
External trigger
Activated through PD pin
Resolution
17 bits
15 bits
15 bits
17 bits or 15 bits
Output data refresh rate
1.8 Hz
9 Hz
Approximately 1 Hz
Electrical Connections
The SCP1000 pressure sensor supports two communication interfaces, SPI and I
2
C. Appropriate
communication interface is pre-programmed in the factory.
SCP1000- D01 (SPI Interface)
Pin #
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Name
ATST
TRIG
(6
DRDY
CLK
DVDD
DVSS
DVDDS
PD
(6
SCK
(6
MOSI
(6
MISO
CSB
(6
AVDD
AVSS
AVSS
ATST
Function
Connect to analog ground
Trigger input, connect to GND if
not used
Interrupt signal (data ready)
Connect to digital GND
Digital supply voltage
Digital ground
Digital supply filter
Power down, connect to GND if
not used
SPI clock input
SPI data input
SPI data output
SPI chip select
Analog supply voltage
Analog ground
Analog ground
Connect to analog ground
Characteristics
For factory use only
Digital input
Digital output
Power line
Power line
Digital power supply filter
Input to force the chip in power down
mode
Interface clock
Digital data input
Digital data output
Digital input
Power line
Power line
Power line
For factory use only
Note 6 The MCU has to actively drive the signal in high and low states