NTF Series  
Isolated 1W Wide Input DC/DC Converters  
TEMPERATURE CHARACTERISTICS  
Parameter  
Operation  
Storage  
Conditions  
See derating graphs  
Min.  
-40  
Typ.  
30  
Max.  
85  
Units  
ºC  
-50  
130  
Cooling  
Free air convection  
Case temperature rise above  
ambient  
ISOLATION CHARACTERISTICS  
Parameter  
Isolation test voltage  
Resistance  
Conditions  
Flash tested for 1 second  
Viso= 500VDC  
Min.  
1000  
1
Typ.  
Max.  
Units  
VDC  
GΩ  
pF  
10  
25  
Capacitance  
TECHNICAL NOTES  
ISOLATION VOLTAGE  
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,  
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.  
Murata Power Solutions NTF series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.  
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”  
For a part holding no specific agency approvals, such as the NTF series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or  
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part  
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must  
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to  
safety standard requirements.  
REPEATED HIGH-VOLTAGE ISOLATION TESTING  
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,  
construction and environment. The NTF series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While  
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically  
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We  
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.  
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further  
insulation system of physical spacing or barriers.  