MPDTH***10 Series
Adjustable Non-isolated 12/15-Amp
POLA DC/DC Converters
MECHANICAL SPECIFICATIONS
Surface Mount Models MPDTH_WAS
Through-hole Pins Models MPDTH_WAH
34.80
34.80
3.18
3.18
3.55
3.18
3.18
9.57
MAX
1.52
9.52
10
15.88
1.52
1.52
φ 1.02
5 Places
9.52
1.52
15.88
7
6
9
4
8
1
7
6
10
9
4
8
1
Solder Ball
φ 1.02
10 Places
2
3
5
Host Board
2
TOP VIEW
9.00
MAX
3
5
SIDE VIEW
SIDE VIEW
TOP VIEW
Dimensions are in mm.
Dimensions are in millimeters.
Third Angle Projection
PIN NUMBER AND FUNCTION
Pin
1
Function
Ground
Pin
6
Function
Output (Vout)
Ground
2
Input (Vin)
7
Tolerances (unless otherwise specified):
.XX 0.02 (0.5)
.XXX 0.010 (0.25)
Angles 2ꢁ
3
Inhibit remote On/Off control
Vout Adjust (trim)
Vout Sense
8
Track Input
4
9
Margin Down Input
Margin Up Input
5
10
Components are shown for reference only.
MAXIMUM SAFE OPERATING AREA (DERATING)
MPDTH03010
MPDTH05010
MPDTH12010
90
80
70
60
50
40
30
20
90
80
90
80
70
60
50
40
30
Natural Convection
70
Natural Convection
100 LFM
Natural Convection
100 LFM
100 LFM
200 LFM
400 LFM
200 LFM
400 LFM
60
50
200 LFM
400 LFM
40
30
20
20
0
0
2
4
6
8
10
12
3
6
9
12
15
0
3
6
9
12
15
Iout - Amps
Iout - Amps
Iout - Amps
Vout = 2.5V, Vin = 3.3V
Vout = 3.3V
Vout = 5.0V
Units soldered to a 4" x 4" 4-layer PCB
with 1 oz. copper.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000