■ Specifications and Test Methods
No Item
16 Durability
Specification
Test Method(Ref. Standard:JIS C 5101, IEC60384)
Appearance
Capacitance Change
Q or D.F.
No defects or abnormalities.
Within +/-12.5%
DF≦0.05
Mounting method
Pre-treatment
Solder the capacitor on the test substrate
Voltage treatment:Apply the test voltage at the test temperature for 1hour and then let sit for
24+/-2hours at room temperature, then measure.
Maximum Operating Temperature +/-3℃
1000+/-12h
I.R.
More than 50Ω・F
Test Temperature
Test Time
Test Voltage
200% of the rated voltage
Charge/discharge current 50mA max.
Post-treatment
Non treatment:Let sit for 24+/-2hours at room temperature, then measure.
GRM43RR71H224MA01-01C
4