 浏览型号GQM0335C2D9R2WB01#的Datasheet PDF文件第1页浏览型号GQM0335C2D9R2WB01#的Datasheet PDF文件第3页浏览型号GQM0335C2D9R2WB01#的Datasheet PDF文件第4页浏览型号GQM0335C2D9R2WB01#的Datasheet PDF文件第5页浏览型号GQM0335C2D9R2WB01#的Datasheet PDF文件第6页浏览型号GQM0335C2D9R2WB01#的Datasheet PDF文件第7页浏览型号GQM0335C2D9R2WB01#的Datasheet PDF文件第8页浏览型号GQM0335C2D9R2WB01#的Datasheet PDF文件第9页  
Specifications and Test Methods  
No Item  
Specification  
Test Method(Ref. Standard:JIS C 5101, IEC60384)  
Shown in Rated value.  
The rated voltage is defined as the maximum voltage which may be applied continuously to the capacitor.  
When AC voltage is superimposed on DC voltage, V(peak to peak) or V(zero to peak),  
whichever is larger, should be maintained within the rated voltage range.  
1 Rated Voltage  
No defects or abnormalities.  
Shown in Dimension.  
Visual inspection  
2 Appearance  
3 Dimension  
Using Measuring instrument of dimension.  
No defects or abnormalities.  
Measurement Point  
Test Voltage  
Applied Time  
Between the terminations  
250% of the rated voltage  
1s to 5s  
4 Voltage proof  
Charge/discharge current 50mA max.  
Measurement Temperature  
Measurement Point  
Measurement Voltage  
Charging Time  
More than 10000MΩ  
Room Temperature  
Between the terminations  
Rated Voltage  
5 Insulation  
Resistance(I.R.)  
(Room Temperature)  
1min  
Charge/discharge current 50mA max.  
Measurement Temperature  
Shown in Rated value.  
Room Temperature  
6 Capacitance  
Measurement Frequency 1.0+/-0.1MHz  
Measurement Voltage  
0.5 to 5.0Vrms  
Measurement Temperature  
Q400+20C C:Nominal Capacitance(pF)  
Room Temperature  
7 Q or Dissipation Factor  
(D.F.)  
Measurement Frequency 1.0+/-0.1MHz  
Measurement Voltage 0.5 to 5.0Vrms  
No bias  
Nominal values of the temperature coefficientis is  
The capacitance change should be measured after 5 min at each specified temp. stage.  
Capacitance value as a reference is the value in "*" marked step.  
8 Temperature  
Characteristics of  
Capacitance  
shown in Rated value. But, the Capacitance Change  
under Reference Temperature is shown inTable A.  
Capacitance Drift: Within +/-0.2% or +/-0.05pF  
(Whichever is larger.)  
Capacitance Drift  
The capacitance drift is calculated by dividing the differences between the maximum and minimum  
measured values in the step 1,3 and 5 by the cap. value in step 3.  
Temperature Step  
No removal of the terminations or other defect should occur.  
Mounting method  
Applied Force  
Solder the capacitor on the test substrate  
2N  
9 Adhesive Strength of  
Termination  
Holding Time  
10+/-1s  
Applied Direction  
In parallel with the test substrate and vertical with the capacitor side  
GQM0335C2D9R2WB01-01A  