欢迎访问ic37.com |
会员登录 免费注册
发布采购

DE21XE2102JA4B 参数 Datasheet PDF下载

DE21XE2102JA4B图片预览
型号: DE21XE2102JA4B
PDF下载: 下载PDF文件 查看货源
内容描述: 安全规格认证型陶瓷电容器/高压陶瓷电容器 [Safety Standard Certified Ceramic Capacitors/ High Voltage Ceramic Capacitors]
分类和应用: 电容器陶瓷电容器高压
文件页数/大小: 83 页 / 1655 K
品牌: MURATA [ muRata ]
 浏览型号DE21XE2102JA4B的Datasheet PDF文件第24页浏览型号DE21XE2102JA4B的Datasheet PDF文件第25页浏览型号DE21XE2102JA4B的Datasheet PDF文件第26页浏览型号DE21XE2102JA4B的Datasheet PDF文件第27页浏览型号DE21XE2102JA4B的Datasheet PDF文件第29页浏览型号DE21XE2102JA4B的Datasheet PDF文件第30页浏览型号DE21XE2102JA4B的Datasheet PDF文件第31页浏览型号DE21XE2102JA4B的Datasheet PDF文件第32页  
• Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.  
• This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please review our product specifications or consult the approval sheet for product specifications before ordering.  
!Note  
C85E.pdf  
Jul.13,2011  
Safety Certified Ceramic Capacitors !Caution  
!Caution (Rating)  
1. Operating Voltage  
When DC-rated capacitors are to be used in AC or ripple  
current circuits, be sure to maintain the Vp-p value of the  
applied voltage or the Vo-p that contains DC bias within  
the rated voltage range.  
When the voltage is applied to the circuit, starting or  
stopping may generate irregular voltage for a transit  
period because of resonance or switching. Be sure to  
use a capacitor with a rated voltage range that includes  
these irregular voltages.  
Voltage  
DC Voltage  
DC+AC Voltage  
AC Voltage  
Pulse Voltage (1)  
Pulse Voltage (2)  
5
Positional  
Measurement  
V0-p  
V0-p  
Vp-p  
Vp-p  
Vp-p  
2. Operating Temperature and Self-generated Heat  
(Apply to B/E/F Char.)  
Keep the surface temperature of a capacitor below the  
upper limit of its rated operating temperature range. Be  
sure to take into account the heat generated by the  
capacitor itself. When the capacitor is used in a high-  
frequency current, pulse current or similar current, it may  
have self-generated heat due to dielectric loss. Applied  
voltage load should be such that self-generated heat is  
within 20°C under the condition where the capacitor is  
subjected to an atmospheric temperature of 25°C. When  
measuring, use a thermocouple of small thermal  
capacity-K of ø0.1mm under conditions where the  
capacitor is not affected by radiant heat from other  
components or wind from surroundings. Excessive heat  
may lead to deterioration of the capacitor's characteristics  
and reliability. (Never attempt to perform measurement  
with the cooling fan running. Otherwise, accurate  
measurement cannot be ensured.)  
3. Test Condition for Withstanding Voltage  
(1) Test Equipment  
Test equipment for AC withstanding voltage should be  
used with the performance of the wave similar to  
50/60Hz sine wave.  
If the distorted sine wave or overload exceeding the  
specified voltage value is applied, a defect may be  
caused.  
Continued on the following page.  
26  
 复制成功!