欢迎访问ic37.com |
会员登录 免费注册
发布采购

DMS-20LCD 参数 Datasheet PDF下载

DMS-20LCD图片预览
型号: DMS-20LCD
PDF下载: 下载PDF文件 查看货源
内容描述: 3.5数字液晶显示数字面板电压表 [3½ Digit, LCD Display Digital Panel Voltmeters]
分类和应用:
文件页数/大小: 6 页 / 258 K
品牌: MURATA-PS [ MURATA POWER SOLUTIONS INC. ]
 浏览型号DMS-20LCD的Datasheet PDF文件第1页浏览型号DMS-20LCD的Datasheet PDF文件第2页浏览型号DMS-20LCD的Datasheet PDF文件第3页浏览型号DMS-20LCD的Datasheet PDF文件第4页浏览型号DMS-20LCD的Datasheet PDF文件第6页  
DMS-20LCD Series
3�½ Digit, LCD Display Digital Panel Voltmeters
APPLICATIONS
R
Shunt
= R1 = V
Fsr
/ I
Fsr
Where:
V
Fsr
= Full scale reading (in Volts)
I
Fsr
= Relative full scale current (in Amps)
Example: For a meter with a 2V full scale input (1.999 full
scale reading) and a desired full scale display reading of
1000 (with an input of 20mA), V
Fsr
= 1.000 Volts
R
Shunt
= 1.000V/(0.020 – 0.004)A
R
Shunt
= 1.000V/0.016A = 62.5 Ohms
REF OUT
8
Therefore, the 9V battery voltage appears to the meter inputs as 0.9V.
With the decimal point moved to its DP2 position
(pin 5 tied to pin 3), the meter reads 9.00 Volts.
The circuit can be calibrated by first measuring the actual battery volt-
age with another meter and then adjusting the gain-adjust potentiom-
eter on the back of the DMS-20LCD until a similar reading is obtained.
If possible, the resistors in the divider should be ±1% metal-film types
with TCR’s less than 50ppm/°C.
DMS-20LCD-1-9
11
(+) IN HI
R1
45.3k
To calibrate the circuit of Figure 7, perform the following:
1. With 4mA applied, adjust the 50k potentiometer (R2) to
display a reading of "000" (assuming that is the desired
reading).
2. With 20mA applied, adjust the gain-adjust potentiometer on
the back of the meter to display a reading of "1999". For different full
scale readings, alter the value of R
Shunt
accordingly.
REF IN
7
1
+BAT
9V
BATTERY
+
12
(–) IN LO
R2
10.1k
3
–BAT
5
DP2
R3
45.3k
11
(+) IN HI
10
ANA COMM
12
(–) IN LO
DMS-20LCD-1-5
8
REF OUT
Figure 8. Power Supply Monitor
(9V-Powered Models)
4-20mA
6. Power Supply Monitoring:
A popular application for DATEL’s low-
power LCD meters is monitoring the supply voltage in battery-oper-
ated portable equipment. Figure 8 demonstrates how a 9V-powered
DMS-20LCD can be used to monitor its own supply. The meter used
is the DMS-20LCD-1-9. A three-resistor voltage divider is used to
attenuate the battery voltage and also to satisfy the requirement that
the input voltages applied to pins 12 and 11 be at least 1.5 Volts above
and below the battery voltage applied to pins 1 (+BATTERY) and 3
(–BATTERY). The divider should be designed so that 1/10th the bat-
tery voltage falls across the inputs to the meter:
R2
= 0.1
(R1 + R2 + R3)
+
R1
7
REF IN
1
3
5V RET
R2
+5V SUP
50k
7. External Gain Adjustment:
Connect REFERENCE OUT
(pin 8) to REFERENCE IN (pin 7) for normal, factory calibrated,
operation. Use the circuit shown in Figure 9 for applications needing
external gain adjustment. Calibration is performed with a precise,
near-full-scale, input voltage.
11
(+) IN HI
120 VAC
DATEL
UPA-5/500
DMS-20LCD
OUT
VOLTAGE
12
CALIBRATOR
COM
3
5V RET/
–BAT IN
12
(–) IN LO
10
ANA
COMM
8
NC
8.06k, 1%
7
REF
IN
2k
17.4k, 1%
1
+5V IN/
+BAT IN
Connections
for ±2V, ±20V
and ±200V models
AC to DC Converter
Figure 7. 4-to-20mA Current Loop Operation
(5V-Powered Models)
For +5V models, tie (–) IN LO to pin 3.
For +9V models, tie (–) IN LO to pin 10
732, 1%
200
= 10 to 20 Turns
24.3k, 1%
Connections
for ±200mV
models
Figure 9. External Gain Adjustment
www.murata-ps.com
Technical enquiries
email: sales@murata-ps.com, tel:
+1 508 339 3000
MPM_DMS20lcd.B03
Page 5 of 6