ACA-20PC Series
Performance/Functional Specifications
Typical at T
A
= +25°C, unless otherwise noted.
➀
Full-Scale Current
(45-450Hz)
➁
ACA-20PC-1-XXX-XX
ACA-20PC-2-XXX-XX
➂
ACA-20PC-3-XXX-XX
ACA-20PC-4-XXX-XX
DMS-30798-C
Overcurrent Rating
➁
Performance
Sampling Rate
Accuracy
➁
Measurement Type
Temperature Drift
(0 = +60°C)
Zero Reading
(Vin = 0 Volts)
Dielectric Withstanding Voltage
Power Supply Voltage
➄
ACA-20PC-X-AC1-RL
(47-99Hz)
ACA-20PC-X-DC1-RL
Power Supply Current
➃
ACA-20PC-X-AC1-RL
(47-99Hz)
ACA-20PC-X-DC1-RL
Power Supply Terminal Block
ACA-20PC-1-AC1-RL and ACA-20PC-2-AC1-RL
(2A and 20A ac-powered models with 4-position terminal blocks):
Wire Size and Type
Insulation Strip Length
Screw Tightening Torque
Maximum Rated Current
Maximum Rated Voltage
12-20AWG (solid), 14-20AWG (stranded)
0.25 inches
4.4 pounds/inches (0.5Nm)
20A with 12AWG solid wire; 15A with
14AWG solid or stranded wire
630V (VDE 0110-V. Group 2)
250V (VDE 0110-V Group 3)
–
–
30
+8
50
+12
mA
mAdc
85
+4.75
120
–
264
+40
Vac
Vdc
2.5 reading per second
±0.15%FS ±6 Counts
Sine wave input, full-wave averaging, rms
calibrated
–
“–001”
–
±0.2
“000”
±0.4
±0.4
“001”
±1
Cnts/°C
Counts
Vdc
Min.
–
–
–
–
–
Typ.
–
–
–
–
–
Max.
1.999
19.99
50.0
100.0
30.0
Units
Amps
Amps
Amps
Amps
Amps
Digital, LED-Display AC Ammeters with
Built-in Current Transformers
Physical/Environmental
Case Material
Dimensions
Weight:
ACA-20PC-1-XXX-XX
ACA-20PC-2-XXX-XX
ACA-20PC-3-XXX-XX
ACA-20PC-4-XXX-XX
DMS-30798-C
1.1 ounces (31 grams)
1.1 ounces (31 grams)
1.3 ounces (37 grams)
1.5 ounces (43 grams)
1.0 ounces (28 grams)
Polycarbonate
1.38”W x 0.88”H. Depth is model dependent
(see mechanical specification)
1.5 x rated full-scale current
➀
The ACA-20PC-1-AC1-RL and ACA-20PC-2-AC1-RL have 4-position on-board
terminal blocks. All other models have 2-position terminal blocks.
➁
Specified full-scale currents are those passing through the built-in CT's
primary(load) circuit, over the frequency of 45-450Hz. The Overcurrent Rating
is a continuous rating that applies to the measured ac load current. It does
not apply to any circuitry external to the meter. Accuracy is guaranteed to the
rated current.
➁
For the ACA-20PC-2-AC1-RL, if the load is connected to the meter's on-board
4-position terminal block, the 20A full scale range requires 12AWG solid
copper wire on all connections. If 14AWG solid copper wire is used, the current
should be limited to 15A. See Figure 3.
➃
All specified maximum power supply currents are steady-state values.
AC-powered models can draw higher surges at initial turn-on.
➄
Maximum reverse polarity protection on "DC1" models is –40Vdc.
Ordering Information
ACA - 20PC - 1 - AC1 - RL - L - C
(45-450Hz)
Input Range:
1
= 1.999A
2
= 19.99A
3
= 50.0A
4
= 100.0A
RoHS
Leaded CT (100A model)
LED Color:
RL
= Red Standard
BL
= Blue Standard
PGL
= Green Standard
Power Supply:
AC1
= 85-264Vac@50/60Hz
DC1
= +5-40Vdc
ACA-20PC-X-XXX-XX
(All other ac or dc-powered models with 2-position terminal blocks):
Wire Size and Type
Insulation Strip Length
Screw Tightening Torque
Display
Display Type and Size
Overrange Indication
Decimal Point
Physical/Environmental
Operating Temperature
Storage Temperature
Humidity (non-condensing)
0
–40
0
–
–
–
+60
+75
95
°C
°C
%
3�½ digit, 0.37"/9.4mm high LED
“1_ _ _“
Fixed, model dependent
16-24AWG (solid or stranded)
0.25 inches
3.6 pounds/inches (0.5Nm)
DMS-30798-C:
30Amp model with a wire lead CT and “-AC1”
power supply specifications. See Mechanical section for dimensions.
Accessories:
DMS-20-CP Panel cutout punch
A DMS-BZL4-C bezel assembly with sealing gasket is supplied with each ammeter.
For full de
www.murata
www.murata-ps.com
Technical enquiries
email: sales@murata-ps.com, tel:
+1 508 339 3000
MPM_ACA_20PC.B05