500-XC6ꢂꢀ2  
aPPliCation Data  
//  
//  
Enꢄine  
Fꢇel Cꢆnsꢇꢈꢃtiꢆn  
Manufacturer  
Model  
MTU Detroit Diesel  
Series 60  
(6063HK36)  
4-Cycle  
At 100% of Power Rating: gal/hr (lit/hr)  
At 75% of Power Rating: gal/hr( lit/hr)  
At 50% of Power Rating: gal/hr (lit/hr)  
35.6 (134.8)  
26.8 (101.4)  
18.7 (70.8)  
Type  
Arrangement  
6-Inline  
//  
Displacement: Cu In (lit)  
Bore: in (cm)  
Stroke: in (cm)  
Compression Ratio  
Rated RPM  
Engine Governor  
Max Power: Standby: bhp (kWm)  
Regulation  
855 (14)  
5.24 (13.3)  
6.61 (16.8)  
15:1  
1,800  
DDEC  
760 (567)  
±.25%  
60 Hz  
Cꢆꢆlinꢄ - radiatꢆꢅ Systeꢈ (Standby)  
Ambient Capacity of Radiator: °F (°C)  
Max. Restriction of Cooling Air, Intake,  
and Discharge Side of Rad.: in. H20 (kPa)  
Water Pump Capacity: gpm (lit/min)  
Heat Rejection to Coolant: BTUM (kW)  
Heat Rejection to Air to Air: BTUM (kW)  
Heat Radiated to Ambient: BTUM (kW)  
122 (50)  
0.5 (0.12)  
111 (420)  
9,650 (170)  
8,200 (144)  
6,421 (113)  
Frequency  
Air Cleaner  
Dry  
//  
Aiꢅ reqꢇiꢅeꢈents  
//  
Liqꢇid Caꢃacity (Lꢇbꢅicatiꢆn)  
Aspirating: *SCFM (m3/min)  
Air Flow Required for Rad.  
Cooled Unit: *SCFM (m3/min)  
Air Flow Required for Heat  
1,514 (43)  
Total Oil System: gal (lit)  
Engine Jacket Water Capacity: gal (lit)  
System Coolant Capacity: gal (lit)  
9.5 (36)  
6 (23)  
27 (102)  
25,873 (733)  
Exchanger/Remote Rad. based  
on 25°F Rise: *SCFM (m3/min)  
14,482 (413)  
//  
Electꢅical  
* Air density = 0.0739 lbm/ft3 (1.184 kg/m3)  
Electric Volts DC  
24  
//  
Cold Cranking Amps Under 0°F (-17.8°C)  
950  
Exhaꢇst Systeꢈ  
Gas Temp. (Stack): °F (°C)  
Gas Volume at Stack  
Temp: CFM (m3/min)  
Maximum Allowable  
1,030 (554)  
4,227 (120)  
40.8 (10.2)  
//  
Fꢇel Systeꢈ  
Fuel Supply Connection Size  
Fuel Return Connection Size  
Maximum Fuel Lift: ft (m)  
Recommended Fuel  
3/4” NPT  
1/2” NPT  
7 (2.1)  
Diesel #2  
105.3 (399)  
Back Pressure: in. H20 (kPa)  