APPLICATION DATA  
//ꢀ  
//ꢀ  
Engine  
Fuel Consumption  
Manufacturer  
Model  
Type  
Arrangement  
Displacement: L (in3)  
Bore: cm (in)  
MTU  
16V 4000 G43  
4-Cycle  
16-V  
76.3 (4,656)  
STANDBY  
558 (147.3)  
426 (112.6)  
299 (78.9)  
At 100% of Power Rating: L/hr (gal/hr)  
At 75% of Power Rating: L/hr (gal/hr)  
At 50% of Power Rating: L/hr (gal/hr)  
17 (6.69)  
//ꢀ  
Stroke: cm (in)  
Compression Ratio  
Rated RPM  
21 (8.27)  
16.5:1  
Cooling - Radiator System  
1,800  
STANDBY  
40 (104)  
Engine Governor  
Maximum Power: kWm (bhp)  
Speed Regulation  
Air Cleaner  
Electronic Isochronous (ADEC)  
Ambient Capacity of Radiator: °C (°F)  
Maximum Restriction of Cooling Air, Intake,  
and Discharge Side of Rad.: kPa (in. H20)  
Water Pump Capacity: L/min (gpm)  
After Cooler Pump Capacity: L/min (gpm)  
Heat Rejection to Coolant: kW (BTUM)  
Heat Rejection to After Cooler: kW (BTUM)  
Heat Radiated to Ambient: kW (BTUM)  
Fan Power: kW (hp)  
2,280 (3,058)  
±0.25%  
0.25 (1)  
1,350 (357)  
583 (154)  
874 (49,704)  
671 (38,160)  
184 (10,478)  
99.4 (133.2)  
Dry  
//ꢀ  
Liquid Capacity (Lubrication)  
Total Oil System: L (gal)  
300 (79.3)  
175 (46.2)  
50 (13.2)  
651 (172)  
Engine Jacket Water Capacity: L (gal)  
After Cooler Water Capacity: L (gal)  
System Coolant Capacity: L (gal)  
//ꢀ  
Air Requirements  
STANDBY  
186 (6,569)  
Aspirating: *m3/min (SCFM)  
Air Flow Required for Rad.  
//ꢀ  
Electrical  
Electric Volts DC  
Cold Cranking Amps Under -17.8 °C (0 °F)  
24  
2,800  
Cooled Unit: *m3/min (SCFM)  
Remote Cooled Applications;  
Air Flow Required for Dissipation  
of Radiated Gen-set Heat for a  
Max of 25 °F Rise: *m3/min (SCFM)  
2,270 (80,160)  
673 (23,631)  
//ꢀ  
Fuel System  
Fuel Supply Connection Size  
Fuel Return Connection Size  
#16 JIC 37° Female * Air density = 1.184 kg/m3 (0.0739 lbm/ft3)  
1” NPT Adapter Provided  
//ꢀ  
#16 JIC 37° Female  
1” NPT Adapter Provided  
1 (3)  
Exhaust System  
Maximum Fuel Lift: m (ft)  
Recommended Fuel  
Total Fuel Flow: L/hr (gal/hr)  
STANDBY  
480 (896)  
Diesel #2  
1,200 (317)  
Gas Temp. (Stack): °C (°F)  
Gas Volume at Stack  
Temp: m3/min (CFM)  
456 (16,103)  
8.5 (34.1)  
Maximum Allowable  
Back Pressure: kPa (in. H20)