ELECTRICAL SPECIFICATIONS
BBF2803S
Parameter
Test Conditions
1
Group A
Subgroup
1
2,3
Output Current 2 8
16V≤V
IN
≤40V
BW=10KHz to 2MHz
1
2,3
1
2,3
1
2,3
1
2,3
1
2,3
1
2,3
Step Load Response
2
I
OUT
=2.75A to/from 5.50A
Transition TIme=30µS
I
OUT
=2.75A to/from 5.50A
Transition TIme=30µS
V
IN
=16V to/from 40V
Transition Time=30µS
V
IN
=16V to/from 40V
Transition Time=30µS
I
OUT
=5.5A
4
5,6
4
5,6
4
5,6
4
5,6
4
5,6
4
5,6
4
5,6
-
P
OUT
=18W MAX.
Enabled, I
OUT
=0mA
Disabled I
OUT
=0mA
Capacitive Load 2
Isolation
Short Circuit Current Limit 7
Switching Frequency
VOUT Adjustment Range
R
POT
=50KΩ
No Effect on DC Performance
Input to output or any pin to case @ 500V
1,2,3
1
2,3
1,2,3
1,2,3
1
1
4
1
BBF2803S H/E
Min.
3.20
3.15
500
500
-
-
-
-
-
-
-
-
61
58
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
16
-
-
-
-
100
5.5
475
±10
BBF2803S
Min.
3.18
-
500
-
-
-
-
-
-
-
-
-
61
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
16
-
-
-
-
100
5.5
475
±10
Units
Max.
3.42
-
5500
-
60
-
60
-
±25
-
±20
-
-
-
±700
-
220
-
±800
-
220
-
300
-
60
100
500
-
60
40
40
-
2.5
300
-
8.5
525
-
VDC
VDC
mA
mA
mVrms
mVrms
mArms
mArms
mV
mV
mV
mV
%
%
mV
mV
µS
µS
mV
mV
µS
µS
mV
mV
mS
mS
µS
µS
mS
V
mA
mA
mA
µF
MΩ
A
KHz
%
Typ.
3.30
-
-
-
20
-
20
-
±2
-
±1
-
66
-
±400
-
100
-
±500
-
80
-
0
-
30
-
120
-
20
-
35
-
1.25
-
-
7.8
500
-
Max.
3.40
3.45
5500
5500
50
60
50
60
±20
±50
±15
±40
-
-
±600
±800
200
300
±750
±1000
200
300
300
500
60
100
500
550
60
40
40
50
2.5
300
-
8.5
525
-
Typ.
3.30
-
-
-
20
-
20
-
±2
-
±1
-
66
-
±400
-
100
-
±500
-
80
-
0
-
30
-
120
-
20
-
35
-
1.25
-
-
7.8
500
-
Output Voltage
Output Voltage Ripple
Input Current Ripple 2
BW=10KHz to 2MHz
Line Regulation
V
IN
=16V to 40V
Load Regulation
I
OUT
=0.5A to 5.5A
Efficiency
Step Load Recovery 2
Step Line Response 2
Step Line Recovery 2
Start Up Overshoot
2
Start Up Delay
I
OUT
=5.5A
Shutdown Delay 2
Shutdown Recovery 2
Input Voltage Range 2
Quiescent Current
NOTES:
+V
IN
= 28V, I
OUT
= 5.5A, T
A
=T
C
=25°C unless otherwise specified.
Guaranteed by design but not tested. Typical parameters are representative of actual device performance but are for reference only.
Industrial grade and "E" suffix devices shall be tested to subgroups 1 and 4 unless otherwise specified.
Military grade devices ("H" suffix) shall be 100% tested to subgroups 1, 2, 3 and 4.
Subgroups 5 and 6 testing available upon request.
Subgroup 1, 4 T
A
=T
C
=+25°C
2, 5 T
A
=T
C
=+125°C
3, 6 T
A
=T
C
= -55°C
7 Device has internal shutdown feature that pulses the output with a low duty cycle during faults.
8 At case temperatures above 90°C, the BBF2803 requires VIN>16V to support a 5.5A load. At 125°C, 18V input is required
to support 5.5A output; 16V will support 4A output at 125°C.
1
2
3
4
5
6
3