欢迎访问ic37.com |
会员登录 免费注册
发布采购

ADC121 参数 Datasheet PDF下载

ADC121图片预览
型号: ADC121
PDF下载: 下载PDF文件 查看货源
内容描述: 1W ,微型SIP ,单和双输出DC / DC转换器 [1W, Miniature SIP, Single & Dual Output DC/DC Converters]
分类和应用: 转换器
文件页数/大小: 2 页 / 168 K
品牌: MPSIND [ MPS INDUSTRIES, INC. ]
 浏览型号ADC121的Datasheet PDF文件第1页  
ADC100 SERIES
1W, Miniature SIP, Single & Dual Output DC/DC Converters
Absolute Maximum Ratings
Parameter
5VDC Input Models
Input Surge Voltage
(1000mS)
12VDC Input Models
15VDC Input Models
24VDC Input Models
Lead Temperature
(1.5mm from case for 10sec.)
Internal Power Dissipation
General Characteristics
Min.
-0.7
-0.7
-0.7
-0.7
---
---
Max. Units
9
18
18
30
260
450
VDC
VDC
VDC
VDC
°C
mW
Parameter
Isolation
Voltage
Isolation
Resistance
Isolation
Capacitance
Switching
Frequency
MTBF
Conditions
60 Seconds
500VDC
100kHz, 1V
Min.
1000
1000
---
70
Typ.
---
---
60
100
---
Max.
---
---
100
120
---
Units
VDC
MΩ
pF
kHz
MHrs
MIL-HDBK-217F
@25°C
Ground Benign
2
Exceeding the unit absolute maximum ratings could cause damage.
These are not continuous operating ratings.
Environmental Characteristics
Parameter
Operating
Temperature
Operating
Temperature
Storage
Temperature
Humidity
Cooling
Output Characteristics
Max. Units
85
90
125
°C
°C
°C
%
Parameter
Line Regulation
Load Regulation
Ripple & Noise
Short Circuit
Conditions
For Vin Change of
1%
Io = 20% to 100%
20MHz BW
Min.
---
Typ.
±1.2
Max.
±1.5
Units
%
%
mV P-P
Conditions
Ambient
Case
Min.
-40
-40
-40
See Selection Guide
---
50
75
---
95
Free-Air Convection
0.5 Second Max.
Maximum Capacitive Load
Models by Output Voltage
(Each Output on Duals)
Singles
220
Duals
100
Units
uF
Derating Curve
100
80
Output Power (%)
100LFM
400LFM
200LFM
Notes:
1. Specifications typical at Ta=+25°C, resistive load, nominal input
voltage, rated output current unless otherwise noted.
2. These power converters require a minimum output load to maintain
specified regulation.
3. Operation under no-load conditions will not damage these modules;
however, they may not meet all specifications listed.
4. All DC/DC converters should be externally fused at the front end for
protection.
5. Other input and output voltage may be available, please contact
factory.
6. All specifications subject to change without notice.
7. For detailed data sheet, please visit our website.
60
Natural
convection
40
20
0
-40
¡ã
50
60
70
80
]
90
100
110
Ambient Temperature
2463 208th Street, Ste. 205
Torrance, CA 90501
Tel: (310) 533-1455
Fax: (310) 533-1853
http://www.mpsind.com
E-mail: sales@mpsind.com