欢迎访问ic37.com |
会员登录 免费注册
发布采购

MP6215 参数 Datasheet PDF下载

MP6215图片预览
型号: MP6215
PDF下载: 下载PDF文件 查看货源
内容描述: 3.3V / 5V ,单通道1.5A限流配电开关 [3.3V/5V, Single-Channel 1.5A Current-Limited Power Distribution Switch]
分类和应用: 开关
文件页数/大小: 10 页 / 658 K
品牌: MPS [ MONOLITHIC POWER SYSTEMS ]
 浏览型号MP6215的Datasheet PDF文件第2页浏览型号MP6215的Datasheet PDF文件第3页浏览型号MP6215的Datasheet PDF文件第4页浏览型号MP6215的Datasheet PDF文件第5页浏览型号MP6215的Datasheet PDF文件第6页浏览型号MP6215的Datasheet PDF文件第8页浏览型号MP6215的Datasheet PDF文件第9页浏览型号MP6215的Datasheet PDF文件第10页  
MP6215 –CURRENT-LIMITED POWER DISTRIBUTION SWITCH  
FUNCTION BLOCK DIAGRAM  
UVLO  
+
Vref  
OUT  
IN  
Current  
Sense  
--  
--  
-- -- --  
Charge  
Pump  
--  
AMP  
Logic  
+
-- FLAG  
EN  
Deglich  
Thermat  
Sense  
--  
GND  
Figure2—Functional Block Diagram  
DETAILED DESCRIPTION  
3Output current has been gradually increased  
beyond the recommended operating current.  
The load current rises until the trip current  
threshold is reached or until the thermal limit  
of the device is exceeded. The MP6215 is  
capable of delivering current up to the trip  
current threshold without damaging the  
device. Once the trip threshold has been  
reached, the device switches into its constant-  
current mode.  
Over Current  
When the load exceeds trip current (minimum  
threshold current triggering constant-current  
mode) or a short is present, MP6215 switches  
into to a constant-current mode (current limit  
value). MP6215 will be shutdown only if the  
overcurrent condition stays long enough to  
trigger thermal protection.  
Trigger overcurrent protection for different  
overload conditions occurring in applications:  
1) The output has been shorted or overloaded  
before the device is enabled or input applied.  
MP6215 detects the short or overload and  
immediately switches into a constant-current  
mode.  
2) A short or an overload occurs after the device  
is enabled. After the current-limit circuit has  
been tripped (reached the trip current  
threshold), the device switches into constant-  
current mode. However, high current may  
flow for a short period of time before the  
current-limit circuit can react.  
Flag Response  
The FLAG pin is an open drain configuration.  
This FAULT will report a fail mode after an 8ms  
deglitch timeout. This is used to ensure that no  
false fault signals are reported. This internal  
deglitch circuit eliminates the need for extend  
components. The FLAG pin is not deglitched  
during an over temp. or a voltage lockout.  
MP6215 Rev. 0.9  
3/23/2010  
www.MonolithicPower.com  
MPS Proprietary Information. Unauthorized Photocopy and Duplication Prohibited.  
© 2010 MPS. All Rights Reserved.  
7