MP174 – NON-ISOLATED OFF-LINE REGULATOR  
ABSOLUTE MAXIMUM RATINGS (1)  
Drain to source .............................-0.3V to 700V  
All other pins..................................-0.3V to 6.5V  
Thermal Resistance (4)  
TSOT23-5..............................100..... 55... °C/W  
SOIC-8....................................96...... 45... °C/W  
θJA  
θJC  
(2)  
Continuous Power Dissipation....(TA = +25°C)  
Notes:  
TSOT23-5..................................................... 1W  
SOIC8........................................................... 1W  
Junction Temperature...............................150°C  
Lead Temperature ....................................260°C  
Storage Temperature............... -60°C to +150°C  
ESD Capability Human Body Mode.......... 2.0kV  
ESD Charged Device Model  
1) Exceeding these ratings may damage the device.  
2) The maximum allowable power dissipation is a function of the  
maximum junction temperature TJ(MAX), the junction-to-  
ambient thermal resistance θJA, and the ambient temperature  
TA. The maximum allowance continuous power dissipation at  
any  
ambient  
temperature  
is  
calculated  
by  
PD(MAX)=(TJ(MAX)-TA)/θJA. Exceeding the maximum  
allowance power dissipation will cause excessive die  
temperature, and the regulator will go into thermal shutdown.  
Internal thermal shutdown circuit protects the device from  
permanent damage.  
TSOT23-5................................................. 1.5kV  
SOIC8....................................................... 2.0kV  
3) The device is not guaranteed to function outside of its  
operating conditions.  
4) Measured on JESD51-7, 4-layer PCB.  
Recommended Operating Conditions (3)  
Operating Junction Temp. (TJ). -40°C to +125°C  
Operating VCC range .....................5.3V to 5.6V  
MP174 Rev. 1.01  
8/18/2016  
www.MonolithicPower.com  
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.  
© 2016 MPS. All Rights Reserved.  
3