ABSOLUTE MAXIMUM RATINGS (1)
DRAIN to SOURCE ..................... -0.3V to 700V
VCC to SOURCE........................... -0.3V to 30V
FB to SOURCE................................ -0.3V to 7V
SOURCE to GND ......................... -15V to 700V
STBY, INA, INB, VO to GND............ -0.3V to 7V
VIN, OUTA, OUTB to GND............ -0.3V to 30V
Thermal Resistance (4) θJA
SOIC-16................................ 80.......30 ... °C/W
θJC
NOTES:
1) Exceeding these ratings may damage the device.
2) The maximum allowable power dissipation is a function of the
maximum junction temperature TJ(MAX), the junction-to-
ambient thermal resistance θJA, and the ambient temperature
TA. The maximum allowance continuous power dissipation at
any ambient temperature is calculated by PD(MAX)=(TJ(MAX)-
TA)/θJA. Exceeding the maximum allowance power dissipation
produces an excessive die temperature, causing the regulator
to go into thermal shutdown. Internal thermal shutdown circuit
protects the device from permanent damage.
(2)
Continuous power dissipation (TA = +25°C)
................................................................1.56W
Junction temperature...............................150°C
Lead temperature ....................................260°C
Storage temperature................-60°C to +150°C
ESD charged device model ......................2.0kV
3) The device is not guaranteed to function outside of its
operating conditions.
4) Measured on JESD51-7, 4-layer PCB.
Recommended Operating Conditions (3)
Junction temperature (TJ) ........-40°C to +125°C
MP161 Rev. 1.0
8/4/2017
www.MonolithicPower.com
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2017 MPS. All Rights Reserved.
4