MP1530 – TRIPLE OUTPUT STEP-UP PLUS LINEAR REGULATORS FOR TFT BIAS  
PIN FUNCTIONS  
QFN TSSOP  
Name Description  
Pin #  
Pin #  
Step-Up Converter Power Switch Node. Connect an inductor between the input source  
1
15  
SW and SW, and connect a rectifier from SW to the main output to complete the step-up  
converter. SW is the drain of the internal 250mN-Channel MOSFET switch.  
Timing Capacitor for Power Supply Soft-Start and Power-On Sequencing. A capacitor  
CT from CT to GND controls the soft-start and sequencing turn-on delay periods. See  
Power-On Sequencing and Start Up Timing Diagram.  
2
3
16  
1
Regulators Not Ready. During startup RDY will be left high. Once the turn-on sequence  
is complete, this pin will be pulled low if all FB voltages exceed 80% of their specified  
thresholds. After all regulators are turned-on, a fault in any regulator that causes the  
RDY  
respective FB voltage to fall below 80% of its threshold will cause RDY to go high after  
approximately 15μs. If the fault persists for more than approximately 6ms (for CCT=10nF),  
the entire chip will shut down. See Fault Sensing and Timer.  
Step-Up Converter Feedback Input. FB1 is the inverting input of the internal error  
FB1 amplifier. Connect a resistive voltage divider from the output of the step-up converter to  
FB1 to set the step-up converter output voltage.  
Step-Up Converter Compensation Node. COMP is the output of the error amplifier.  
COMP Connect a series RC network to compensate the regulation control loop of the step-up  
converter.  
4
5
2
3
Internal Power Input. IN supplies the power to the MP1530. Bypass IN to PGND with a  
10μF or greater capacitor.  
GND Signal Ground.  
6
7
4
5
IN  
Reference Output. REF is the 1.25V reference voltage output. Bypass REF to GND with  
REF a 0.1μF or greater capacitor. Connect REF to the low-side resistor of the negative linear  
regulator feedback string.  
Negative Linear Regulator Feedback Input. Connect the FB2 feedback resistor string  
FB2 between GL and REF to set the negative linear regulator output voltage. FB2 regulation  
threshold is GND.  
Positive Linear Regulator Feedback Input. Connect the FB3 feedback resistor string  
FB3 between GH and GND to set the positive linear regulator output voltage. FB3 regulation  
threshold is 1.25V.  
8
9
6
7
8
10  
On/Off Control Input. Drive EN high to turn on the MP1530, drive EN low to turn it off. For  
automatic startup, connect EN to IN. Once the MP1530 is turned on, it sequences the  
outputs on (See Power-On Sequencing). When turned off, all outputs are immediately  
11  
9
EN  
disabled.  
Negative Linear Regulator Output. GL is the output of the negative linear regulator. GL  
GL can supply up to 20mA to the load. Bypass GL to GND with a 1μF or greater, low-ESR,  
ceramic capacitor.  
Negative Linear Regulator Input. IN2 is the input of the negative linear regulator. Drive  
IN2 IN2 with an inverting charge pump powered from SW. IN2 can go as low as -20V. For  
QFN package, connect the exposed pad to IN2 pin.  
12  
13  
10  
11  
MP1530 Rev. 1.41  
5/25/2011  
www.MonolithicPower.com  
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.  
© 2011 MPS. All Rights Reserved.  
6