MP1039 – FULL BRIDGE CCFL CONTROLLER  
Careful management of limit conditions  
provides graceful reduction of lamp power at  
low supply voltages but allows the loop to  
recover quickly from an abrupt step in supply  
voltage. System fault management facilities  
include an on-chip open-lamp regulator, a  
transformer secondary peak current regulator,  
and a dual-mode fault timer.  
The MP1039 does not utilize ZVS or ZCS. It  
implements fast switching to reduce switching  
loss and operates at the condition that IPRI and  
VPRI are in phase to reduce primary RMS  
current. Therefore, higher efficiency than ZVS  
or ZCS is achieved.  
V
V
PS  
PS  
A
B
C
D
By regulating the peak current in the  
transformer secondary winding, UL60950 can  
be met for most systems. When the MP1039 is  
regulating open lamp voltage, it ignores the  
burst control and runs continuously to ensure  
either the lamp has a chance to re-ignite or the  
fault timer can smoothly and accurately time  
out. If the MP1039 detects an open lamp  
condition for a time that exceeds the timer  
interval, it will shut down until the part is turned  
off and then turned on again. Similarly, the  
MP1039 will shut down if it detects an over-  
current condition in the secondary for about 2%  
of the open lamp timer interval. If required, the  
secondary over-current timeout can be  
shortened with external components.  
D1  
V
PRI  
-
+
I
PRI  
A,D  
B,C  
V
I
:
:
PRI  
ZVS  
ZCS  
0
0
0
PRI  
MP1039  
FEATURE DESCRIPTION  
All reference designators refer to Figure 1,  
unless otherwise designated.  
Figure 2—VPRI vs. IPRI  
Brightness Control  
The MP1039 can operate in four modes:  
Analog Mode, Burst Mode with a DC input,  
Burst Mode with an external PWM or Analog  
and Burst Mode. The four modes are  
dependent on the pin connections defined  
under Pin Functions.  
High Efficiency Operation  
There are two major power losses in a CCFL  
inverter: switching loss of switches and copper  
loss of the transformer winding. To reduce  
switching loss, Zero Current Switching (ZCS as  
described in US patent 6,114,814) or Zero Voltage  
Switching (ZVS) are commonly implemented.  
Choosing the required burst repetition  
frequency can be achieved by an RC  
combination, as defined in component  
selection. The MP1039 has a soft-on and  
soft-off feature to reduce noise, when using  
burst mode dimming. Analog dimming and  
Burst dimming are independent of each other  
and may be used together to obtain a wider  
dimming range.  
As shown in Figure 2, ZCS and ZVS require  
primary current IPRI lagging primary voltage VPRI  
With ZVS, since D1 can only conduct at the  
negative phase of IPRI, the beginning of A & D  
conduction will only happen at the negative  
phase of IPRI.  
.
Higher phase delay will lead to higher primary  
RMS current and therefore higher transformer  
temperature. With ZCS, A & D conduction starts  
at the zero crossing of IPRI.  
MP1039 Rev. 1.1  