MP1011A
Cold Cathode Fluorescent Lamp Driver
Table 2:
Leakage Inductance Guide Lines for Minimum Operating Voltage
Minimum Operating Supply
Voltage
6
7
8
9
10
Recommended Maximum Primary
Leakage Inductance*
38µH
42µH
45µH
47µH
49µH
∗
If the maximum primary leakage cannot be met, consult factory for alternatives.