欢迎访问ic37.com |
会员登录 免费注册
发布采购

D103EHI 参数 Datasheet PDF下载

D103EHI图片预览
型号: D103EHI
PDF下载: 下载PDF文件 查看货源
内容描述: 低成本,微型SIP 1W ,非常高隔离的DC / DC转换器 [Low Cost, Miniature SIP 1W, Very High Isolation DC/DC Converters]
分类和应用: 转换器
文件页数/大小: 2 页 / 175 K
品牌: MPD [ MICROPOWER DIRECT, LLC ]
 浏览型号D103EHI的Datasheet PDF文件第1页  
Model Selection Guide  
Input  
Output  
Current  
Fuse Rating  
Slow-Blow  
(mA)  
Model  
Efficiency  
(%, Typ)  
Voltage (VDC)  
Current (mA)  
Voltage  
(VDC)  
Current  
Number  
(mA, Max) (mA, Min)  
Nominal  
Range  
Full-Load  
No-Load  
D101EHI  
D102EHI  
D103EHI  
D104EHI  
D105EHI  
D106EHI  
D107EHI  
D108EHI  
D111EHI  
D112EHI  
D113EHI  
D114EHI  
D115EHI  
D116EHI  
D117EHI  
D118EHI  
5
5
5
5
5
5
5
5
12  
12  
12  
12  
12  
12  
12  
12  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
286  
286  
278  
278  
277  
277  
267  
267  
113  
113  
110  
110  
111  
111  
107  
107  
60  
60  
60  
60  
60  
60  
60  
60  
40  
40  
40  
40  
40  
40  
40  
40  
5.0  
9.0  
12.0  
15.0  
5.0  
200  
111  
84  
67  
100  
56  
42  
33  
200  
111  
84  
67  
100  
56  
42  
33  
20.0  
12.0  
9.0  
7.0  
10.0  
6.0  
5.0  
4.0  
20.0  
12.0  
9.0  
7.0  
10.0  
6.0  
5.0  
4.0  
72  
72  
75  
75  
72  
72  
75  
75  
74  
74  
76  
76  
75  
75  
78  
78  
1,000  
1,000  
1,000  
1,000  
1,000  
1,000  
1,000  
1,000  
250  
250  
250  
250  
250  
9.0  
12.0  
15.0  
5.0  
9.0  
12.0  
15.0  
5.0  
9.0  
12.0  
15.0  
250  
250  
250  
Notes:  
Derating Curve  
1. Output load regulation is specified for a load change of 10% to  
100%.  
2. These units should not be operated with a load under 10% of full  
load. Operation at no-load may cause damage to the unit.  
3. These converters will operate without external components.  
However, when measuring output ripple, it is recommended that  
an external ceramic  
Input  
Capacitor  
4.7 µF  
12 VDC 2.2 µF  
Output  
Capacitor  
5 VDC 4.7 µF  
9 VDC 2.2 µF  
12 VDC 1.0 µF  
15 VDC 0.47 µF  
capacitor be placed  
from the +Vout pin  
to the -Vout pin for  
single output units  
and from each out-  
put to common for  
dual output units. An  
Vin  
Vout  
5 VDC  
input capacitor will enhance stability over temperature and input  
line variations. Recommended capacitor values are given in the  
table above.  
For applications requiring very low output noise levels, a simple Pi  
filter should be effective. Component values would depend upon  
the application, but capacitor values of 4.7 µF and inductor  
values of 10 µH are often sufficient.  
Mechanical Dimensions  
4. Dual output units may be connected to provide a 10V, 18V, 24V  
or 30 VDC output. To do this, connect the load across the positive  
(+Vout) and negative (-Vout) outputs and float the output com-  
mon  
5. It is recommended that a fuse be used on the input of a power  
supply for protection. See the Model Selection table above for the  
correct rating.  
Pin Connections  
Pin  
Single  
Dual  
+Vin  
-Vin  
1
+Vin  
2
-Vin  
5
-Vout  
-Vout  
6
No Pin Common  
+Vout +Vout  
7
Mechanical Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.01 ( 0.25)  
MicroPower Direct  
www.micropowerdirect.com  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com