欢迎访问ic37.com |
会员登录 免费注册
发布采购

AD1024-24F 参数 Datasheet PDF下载

AD1024-24F图片预览
型号: AD1024-24F
PDF下载: 下载PDF文件 查看货源
内容描述: 非常低的成本, 20W DIN导轨安装单输出AC / DC电源 [Very Low Cost, 20W DIN Rail Mount Single Output AC/DC Power Supplies]
分类和应用:
文件页数/大小: 2 页 / 285 K
品牌: MPD [ MICROPOWER DIRECT, LLC ]
 浏览型号AD1024-24F的Datasheet PDF文件第1页  
Model Selection Guide
Model
Number
AD1020-05F
AD1024-12F
AD1024-24F
AD1024-48F
Rated
Power
(W)
20
24
24
24
Output
Overvoltage
Fuse Rating
Ripple &
Efficiency
Voltage (VAC)
Current (A)
Protection
Slow-Blow
Voltage Current (A) Current (A)
Noise
(%, Typ)
(VDC)
(A)
(VDC)
Max)
Range
(mV P-P)
Universal Range 115 VAC 230 VAC
100 - 240
1.0
0.5
5
4.0
0 ~ 4.0
50
7.0
78
2.0
100 - 240
1.0
0.5
12
2.0
0 ~ 2.0
100
20.0
80
2.0
100 - 240
1.0
0.5
24
1.0
0 ~ 1.0
150
40.0
83
2.0
100 - 240
1.0
0.5
48
0.5
0 ~ 0.5
250
60.0
83
2.0
Input
Output
Notes:
1. Load regulation is specified for a load change of 20% to
100%.
2. Ripple & noise is measured using equipment with 20 Mhz of
bandwidth with the unit under test operating at rated load
and a 110 VAC input. Connection to the unit is made with
a 0.1
µF
/ 630V metalized capacitor & a 47
µF
electrolytic
capacitor connected in parallel.
3. Transient recovery is measured to within a 1% error band
for a load step change of 50% to 100%.
4. Isolation resistance is given for Input/Output and Input/FG.
For Output/FG., it is 50 M
5. Overload protection is power limiting. The unit recovers
automatically when the fault is removed.
6. Over voltage protection is a shut down type. The unit recov-
ers automatically when the fault is removed.
7. To mount the unit to the DIN rail, tilt the unit rearwards from
the top, fitting the mount over the top of the rail. Press back
on the bottom front of the unit until it locks in place on the
rail. To remove the unit from the rail, pull the removal clip at
the bottom rear of the unit downward with a screw driver.
With the clip down, lift up on the unit from the bottom front
until it clears the rail. Before installation or removal all wiring
should be disconnected and the main power to the system
shut off.
8. When wiring the supply, all lines should be as thick and
short as possible. AWG 14 wire is recommended for the
AD1024F
series.
9. The units should be mounted so they are vertically orien-
tated. Air flow (if it is provided) would optimally flow from
the bottom to the top of the unit.
10. It is recommended that a fuse be used on the input of a
power supply for protection. For the
AD1024F
series,
a 250 VAC 2.0A is recommended.
Derating Curve
Mechanical Dimensions
Connections TB 1
Pin
1
2
3
4
5
Function
DC Output (+V)
DC Output (-V)
Frame Ground (FG)
AC/Neutral
AC/Live
Notes:
All dimensions are typical in inches (mm)
Tolerance x.xx =
±
0.01 (
±
0.25)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
TEL: (781) 344-8226
FAX: (781) 344-8481
E-Mail: sales@micropowerdirect.com