欢迎访问ic37.com |
会员登录 免费注册
发布采购

A100UHI 参数 Datasheet PDF下载

A100UHI图片预览
型号: A100UHI
PDF下载: 下载PDF文件 查看货源
内容描述: 超高隔离 [Ultra High Isolation]
分类和应用:
文件页数/大小: 2 页 / 267 K
品牌: MPD [ MICROPOWER DIRECT, LLC ]
 浏览型号A100UHI的Datasheet PDF文件第1页  
Model Selection Guide
Input
Model
Number
A102UHI
A105UHI
Voltage (VDC)
Nominal
12
12
Range
10.8 - 13.2
10.8 - 13.2
Current (mA)
Full-Load No-Load
106
106
15
15
Voltage
(VDC)
12.0
±12.0
www.micropowerdirect.com
Output
Current
(mA, Max)
83
±41.6
Current
(mA, Min)
9.0
±5.0
Efficiency
(%, Typ)
78
78
Fuse Rating
Slow-Blow
(mA)
200
200
Notes:
1. When measuring output ripple, it is recommended that an external 2.2 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each
output to common for dual output units.
2. To meet the level B requirements of EN 55022, EN 61000-4-4 (EFT) and EN 61000-4-5 (Surge), use the input circuit shown below.
3. Operation at no-load will not damage these units. However, they may not meet all specifications. It is recommended that the minimum levels shown above be used.
4. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating.
Input Filter Connection
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
1
11
13
14
16
26
Single
-Vin
NC
-Vout
-Vout
+Vout
+Vin
Dual
-Vin
-Vout
Common
Common
+Vout
+Vin
Mechanical Notes:
All dimensions are typical in inches (mm)
Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
TEL: (781) 344-8226
FAX: (781) 344-8481
E-Mail: sales@micropowerdirect.com