GENERAL DATA — 1-3 WATT DO-41 SURMETIC 30
ELECTRICAL CHARACTERISTICS
(TA = 25°C unless otherwise noted.) VF = 1.5 V Max, IF = 200 mA for all types.
Zener Voltage
(Note 2)
Type No.
(Note 1)
MZD3.9
MZD4.3
MZD4.7
MZD5.1
MZD5.6
MZD6.2
MZD6.8
MZD7.5
MZD8.2
MZD9.1
MZD10
MZD11
MZD12
MZD13
MZD15
MZD16
MZD18
MZD20
MZD22
MZD24
MZD27
MZD30
MZD33
MZD36
MZD39
MZD43
MZD47
MZD51
MZD56
MZD62
MZD68
MZD75
MZD82
MZD91
MZD100
MZD110
MZD120
MZD130
MZD150
MZD160
MZD180
MZD200
Min
3.7
4
4.4
4.8
5.2
5.8
6.4
7
7.7
8.5
9.4
10.4
11.4
12.4
13.8
15.3
16.8
18.8
20.8
22.8
25.1
28
31
34
37
40
44
48
52
58
64
70
77
85
94
104
114
124
138
153
168
188
Max
4.1
4.6
5
5.4
6
6.6
7.2
7.9
8.7
9.6
10.6
11.6
12.7
14.1
15.8
17.1
19.1
21.2
23.3
25.6
28.9
32
35
38
41
46
50
54
60
66
72
79
88
96
106
116
127
141
156
171
191
212
Test
Current
IZT
mA
100
100
100
100
100
100
100
100
100
50
50
50
50
50
50
25
25
25
25
25
25
25
25
10
10
10
10
10
10
10
10
10
10
5
5
5
5
5
5
5
5
5
Zener Impedance at IZT
f = 1000 Hz (Ohm)
Typ
3.8
3.8
3.8
2
1
1
1
1
1
2
2
4
4
5
5
6
6
6
6
7
7
8
8
21
21
24
24
25
25
25
25
30
30
60
60
80
80
110
110
150
150
150
Max
7
7
7
5
2
2
2
2
2
4
4
7
7
10
10
15
15
15
15
15
15
15
15
40
40
45
45
60
60
80
80
100
100
200
200
250
250
300
300
350
350
350
Blocking Voltage
IR = 1
µA
—
—
—
—
1.5
1.5
2
2
3.5
3.5
5
5
7
7
10
10
10
10
12
12
14
14
17
17
20
20
24
24
28
28
34
34
41
41
50
50
60
60
75
75
90
90
Typical
TC
%/°C
–0.06
+0.055
+0.03
+0.03
+0.038
+0.045
+0.05
+0.058
+0.062
+0.068
+0.075
+0.076
+0.077
+0.079
+0.082
+0.083
+0.085
+0.086
+0.087
+0.088
+0.09
+0.091
+0.092
+0.093
+0.094
+0.095
+0.095
+0.096
+0.096
+0.097
+0.097
+0.098
+0.098
+0.099
+0.11
+0.11
+0.11
+0.11
+0.11
+0.11
+0.11
+0.11
Surge Current
@ TL = 25°C
ir – mA
(Note 3)
1380
1260
1190
1070
970
890
810
730
660
605
550
500
454
414
380
344
304
285
250
225
205
190
170
150
135
125
115
110
95
90
80
70
65
60
55
50
45
—
—
—
—
—
NOTE 1. TOLERANCE AND TYPE NUMBER DESIGNATION
The type numbers listed have zener voltage min/max limits as shown.
NOTE 2. ZENER VOLTAGE (VZ) MEASUREMENT
The zener voltage is measured after the test current (IZT) has been applied for 40
±10
milli-
seconds, while maintaining a lead temperautre (TL) of 30°C at a point of 10 mm from the diode
body.
NOTE 3. (ir) NON-REPETITIVE SURGE CURRENT
Maximum peak, non-repetitive reverse surge current of half square wave or equivalent sine
wave pulse of 50 ms duration, superimposed on the test current (IZT).
NOTE 4. SPECIAL SELECTIONS AVAILABLE INCLUDE:
Nominal zener voltages between those shown. Tight voltage tolerances such as
±1%
and
±2%.
Consult factory.
1–3 Watt DO-41 Surmetic 30 Data Sheet
6-50
Motorola TVS/Zener Device Data