V54C3256(16/80/40)4V(T/S/B)
Operating Currents (T = 0 to 70°C, V = 3.3V ± 0.3V)
A
CC
(Recommended Operating Conditions unless otherwise noted)
Max.
Symbol Parameter & Test Condition
-6
-7 / -7PC -8PC
Unit
Note
ICC1
Operating Current
RC = tRCMIN., tRC = tCKMIN
1 bank operation
250
230
210
mA
7
t
.
Active-precharge command cycling,
without Burst Operation
ICC2P
Precharge Standby Current
in Power Down Mode
tCK = min.
CK = Infinity
2
1
2
1
2
1
mA
mA
7
7
ICC2PS
t
CS =VIH, CKE≤ VIL(max)
ICC2N
Precharge Standby Current
in Non-Power Down Mode
CS =VIH, CKE≥ VIL(max)
tCK = min.
tCK = Infinity
55
5
45
5
35
5
mA
mA
ICC2NS
ICC3N
ICC3P
ICC4
No Operating Current
CKE ≥ VIH(MIN.)
65
10
55
10
45
10
mA
mA
mA
t
CK = min, CS = VIH(min)
bank ; active state ( 4 banks)
CKE ≤ VIL(MAX.)
(Power down mode)
Burst Operating Current
tCK = min
170
150
120
7,8
7
Read/Write command cycling
ICC5
ICC6
Auto Refresh Current
270
240
220
mA
t
CK = min
Auto Refresh command cycling
Self Refresh Current
Self Refresh Mode, CKE≤ 0.2V
3
3
3
mA
mA
L-version
1.7
1.7
1.7
(A component rev)
L-version
1.0
1.0
1.0
mA
(B component rev)
Notes:
7. These parameters depend on the cycle rate and these values are measured by the cycle rate under the minimum value of tCK and
RC. Input signals are changed one time during tCK
t
.
8. These parameter depend on output loading. Specified values are obtained with output open.
V54C3256(16/80/40)4V(T/S/B) Rev. 1.6 September 2002
17