MO SEL VITELIC  
V53C8125H  
Notes:  
1.  
I
is dependent on output loading when the device output is selected. Specified I (max.) is measured with the  
C
C
C
C
output open.  
2.  
I
is dependent upon the number of address transitions. Specified I (max.) is measured with a maximum of two  
CC  
CC  
transitions per address cycle in Fast Page Mode.  
3. Specified V (min.) is steady state operating. During transitions, V (min.) may undershoot to Ò1.0 V for a period  
IL  
IL  
not to exceed 20 ns. All AC parameters are measured with V (min.) V and V (max.) V  
.
IL  
SS  
IH  
CC  
4.  
t
(max.) is specified for reference only. Operation within t  
(max.) limits insures that t  
(max.) and t  
RCD  
RCD  
RAC CAA  
(max.) can be met. If t  
is greater than the specified t  
(max.), the access time is controlled by t  
and t  
.
RCD  
RCD  
CAA  
CAC  
5. Either t  
or t  
must be satisified for a Read Cycle to occur.  
RRH  
RCH  
6. Measured with a load equivalent to two TTL inputs and 50 pF.  
7. Access time is determined by the longest of t , t and t  
.
CAP  
CAA CAC  
8. Assumes that t  
t  
(max.). If t  
(max.). If t  
(max.).  
is greater than t  
(max.), t  
will increase by the amount that t  
will increase by the amount that t  
RAD  
RAD  
RCD  
RAD  
RAD  
RAD  
RAC  
RAC  
RAD  
exceeds t  
(max.).  
RAD  
9. Assumes that t  
t  
is greater than t  
(max.), t  
RCD  
RCD  
RCD  
RCD  
exceeds t  
(max.).  
RCD  
10. Assumes that t  
t  
RAD  
11. Operation within the t  
(max.) limit ensures that t  
(max.) can be met. t  
(max.) is specified as a reference  
RAD  
RAC  
RAD  
point only. If t  
is greater than the specified t  
(max.) limit, the access time is controlled by t  
and t  
.
RAD  
RAD  
CAA  
CAC  
12.  
13.  
14.  
t
t
t
, t  
, t  
and t  
are not restrictive operating parameters.  
WCS RWD AWD  
CWD  
(min.) must be satisfied in an Early Write Cycle.  
WCS  
and t are referenced to the latter occurrence of CAS or WE.  
DS  
DH  
15. t is measured between V (min.) and V (max.). AC-measurements assume t = 3 ns.  
T
IH  
IL  
T
16. Assumes a three-state test load (5 pF and a 380 Ohm Thevenin equivalent).  
17. An initial 200 µs pause and 8 RAS-containing cycles are required when exiting an extended period of bias without  
clocks. An extended period of time without clocks is defined as one that exceeds the specified Refresh Interval.  
V53C8125H Rev. 1.7 August 1998  
7